Commands
5-5
IM 760151-17E
5
Command
Function
Page
:IMPedance[:STATe]
Turns ON/OFF the impedance measurement mode or queries the
current setting.
5-43
:IMPedance:SUPerpose?
Queries all settings related to the load current for impedance measurements. 5-43
:IMPedance:SUPerpose:AMPLitude
Sets the amplitude of the load current for impedance measurements or
queries the current setting.
5-43
:IMPedance:SUPerpose:DETaile?
Queries all settings related to the detailed settings of the load current for
impedance measurements.
5-43
:IMPedance:SUPerpose:DETaile:HOLD
Sets the action taken by the WT1600FC (handling of the control signal to
the impedance measurement electronic load device) when hold is activated
or queries the current setting.
5-43
:IMPedance:SUPerpose:DETaile:LIMit
Sets the range of the load current for impedance measurements or queries
the current setting.
5-43
:IMPedance:SUPerpose:DETaile:RATio
Sets the current value per volt of the control signal to the impedance
measurement electronic load device or queries the current setting.
5-43
:IMPedance:SUPerpose:DETaile:WAVeform
Sets the waveform of the load current for impedance measurements or
queries the current setting.
5-43
:IMPedance:SUPerpose:FREQuency?
Queries all settings related to the frequency of the load current for
impedance measurements.
5-43
:IMPedance:SUPerpose:FREQuency:RANGe
Sets the frequency range of the load current for impedance measurements
or queries the current setting.
5-44
:IMPedance:SUPerpose:FREQuency:VALue
Sets the frequency of the load current for impedance measurements
or queries the current setting.
5-44
:IMPedance:SUPerpose:OFFSet
Sets the magnitude of the DC component of the load current for
impedance measurements or queries the current setting.
5-44
:IMPedance:SUPerpose:OUTPut?
Queries all settings related to the output of the load current for
impedance measurements.
5-44
:IMPedance:SUPerpose:OUTPut[:STATe]
Turns ON/OFF the load current for impedance measurements or queries
the current setting.
5-44
:IMPedance:SUPerpose:OUTPut:TYPE
Sets the output type of the load current for impedance measurements or
queries the current setting.
5-44
:IMPedance:VOLTage?
Queries all settings related to the voltage sensing input of impedance
measurements.
5-44
:IMPedance:VOLTage:ESTimate?
Queries the impedance estimates of all impedance measurement elements. 5-44
:IMPedance:VOLTage:ESTimate[:ALL]
Sets the impedance estimates of all impedance measurement elements
collectively.
5-44
:IMPedance:VOLTage:ESTimate:ELEMent<x>
Sets the impedance estimate of the impedance measurement element or
queries the current setting.
5-45
:IMPedance:VOLTage:INITialize
Sets the voltage range to the initial range.
5-45
:IMPedance:VOLTage:MRANge?
Queries the present voltage measurement range.
5-45
:IMPedance:VOLTage:RANGe?
Queries the voltage range mode of all impedance measurement elements.
5-45
:IMPedance:VOLTage:RANGe[:ALL]
Sets the voltage range mode of all impedance measurement elements
collectively.
5-45
:IMPedance:VOLTage:RANGe:ELEMent<x>
Sets the voltage range mode of the impedance measurement element
or queries the current setting.
5-45
5.1 Command List