5-25
IM 760101-11E
Commands
5
:DISPlay[:NUMeric]:HARMonics:LCURsor
Function
Sets the cursor position on the list display for
harmonic measurement or queries the current
setting.
Syntax
:DISPlay[:NUMeric]:HARMonics:
LCURsor {<Order>}
:DISPlay[:NUMeric]:HARMonics:
LCURsor?
<Order> =
{TOTal|DC|<NRf>}
(<NRf> = 1 to
100)
Example
:DISPLAY:NUMERIC:HARMONICS:
LCURSOR TOTAL
:DISPLAY:NUMERIC:HARMONICS:LCURSOR?
-> :DISPLAY:NUMERIC:HARMONICS:
LCURSOR TOTAL
Description • Specify the cursor position in terms of the
harmonic order.
• This command is valid when the display
format of numeric values (
:DISPlay
[:NUMeric]:HARMonics:IAMount
) is set
to
{SINGle|DUAL|SIGMa}
list display.
:DISPlay[:NUMeric]:HARMonics:LIST<x>
Function
Sets the list display item for harmonic
measurement or queries the current setting.
Syntax
:DISPlay[:NUMeric]:HARMonics:
LIST<x> {<Function>,<Element>}
:DISPlay[:NUMeric]:HARMonics:
LIST<x>?
<x> = 1, 2 (Item number)
<Function> =
{U|I|P|S|Q|LAMBda|...}
(See the function selection list (3).”)
<Element> =
{<NRf>|SIGMA|SIGMB|SIGMC}
(<NRf> = 1 to 6)
Example
:DISPLAY:NUMERIC:HARMONICS:
LIST1 U,1
:DISPLAY:NUMERIC:HARMONICS:LIST1?
-> :DISPLAY:NUMERIC:HARMONICS:
LIST1 U,1
Description This command is valid when the display format
of numeric values (
:DISPlay[:NUMeric]:
HARMonics:IAMount
) is set to
{SINGle|
DUAL}
list display.
:DISPlay[:NUMeric]:HARMonics:PRESet
Function
Presets the display order pattern of numerical
display items for harmonic measurement.
Syntax
:DISPlay[:NUMeric]:HARMonics:
PRESet {<NRf>}
<NRf> = 1 to 4
Example
:DISPLAY:NUMERIC:HARMONICS:PRESET 1
Description Regardless of what value (1 to 4) is specified for
<NRf>, the display pattern (order) of the
numerical display items will be the same as the
display order when Reset List Exec of the
Display setting menu, which is displayed on the
WT1600 screen, is executed.For details on the
order of displayed items when reset is executed,
see the WT1600 User’s Manual.
:DISPlay[:NUMeric]:NORMal?
Function
Queries all settings related to the numerical
display for normal measurement.
Syntax
:DISPlay[:NUMeric]:NORMal?
Example
• Example in which the display format of
numeric values (
:DISPlay[:NUMeric]
:NORMal:IAMount
) is set to “<NRf>(split
display)”
:DISPLAY:NUMERIC:NORMAL? ->
:DISPLAY:NUMERIC:NORMAL:
IAMOUNT 4;ITEM1 URMS,1;
ITEM2 UMN,1;ITEM3
UDC,1;...(omitted)
...;ITEM100 NONE;ICURSOR 1
• Example in which the display format of numeric
values (
:DISPlay[:NUMeric]:NORMal:
IAMount
) is set to “ALL (all display)”
:DISPLAY:NUMERIC:NORMAL? ->
:DISPLAY:NUMERIC:NORMAL:
IAMOUNT ALL;FCURSOR URMS
:DISPlay[:NUMeric]:NORMal:FCURsor
Function
Sets the cursor position on the numerical
display (all display) for normal measurement or
queries the current setting.
Syntax
:DISPlay[:NUMeric]:NORMal:
FCURsor {<Function>}
:DISPlay[:NUMeric]:NORMal:FCURsor?
<Function> =
{URMS|UMN|UDC|UAC|IRMS|
...}
(See the function selection list (1).”)
Example
:DISPLAY:NUMERIC:NORMAL:
FCURSOR URMS
:DISPLAY:NUMERIC:NORMAL:FCURSOR? ->
:DISPLAY:NUMERIC:NORMAL:
FCURSOR URMS
Description • Specify the cursor position in terms of the
function.
• This command is valid when the display
format of numeric values (
:DISPlay
[:NUMeric]:NORMal:IAMount
) is set to
“ALL (all display).”
5.5 DISPlay Group
Summary of Contents for wt1600
Page 1: ...Digital Power Meter Communication Interface IM 760101 11E 4th Edition ...
Page 131: ...7 2 IM 760101 11E 7 2 Sample Program Image ...
Page 138: ...Sample Program 7 9 IM 760101 11E 7 7 4 Output of Normal Measurement Data ...
Page 142: ...Sample Program 7 13 IM 760101 11E 7 7 5 Output of Harmonic Measurement Data ...