5-6
IM 760101-11E
Command
Function
Page
:IMAGe:COLor
Sets the color tone of the screen image data to be output or queries the
current setting.
5-45
:IMAGe:FORMat
Sets the output format of the screen image data or queries the current setting. 5-45
:IMAGe:SEND?
Queries the screen image data.
5-45
INPut Group
:INPut?
Queries all settings related to the input element.
5-48
[:INPut]:CFACtor
Sets the crest factor or queries the current setting.
5-48
[:INPut]:CURRent?
Queries all settings related to the current measurement.
5-49
[:INPut]:CURRent:AUTO[:ALL]
Collectively turns ON/OFF the current auto range of all elements.
5-49
[:INPut]:CURRent:AUTO:ELEMent<x>
Turns ON/OFF the current auto range of the element or queries the current
setting.
5-49
[:INPut]:CURRent:RANGe?
Queries the current ranges of all elements.
5-49
[:INPut]:CURRent:RANGe[:ALL]
Collectively sets the current ranges of all elements.
5-49
[:INPut]:CURRent:RANGe:ELEMent<x>
Sets the current range of the element or queries the current setting.
5-49
[:INPut]:CURRent:SRATio?
Queries the current sensor scaling constants of all elements.
5-50
[:INPut]:CURRent:SRATio[:ALL]
Collectively sets the current sensor scaling constants of all elements.
5-50
[:INPut]:CURRent:SRATio:ELEMent<x>
Sets the current sensor scaling constant of the element or queries the current
setting.
5-50
[:INPut]:CURRent:TERMinal?
Queries the current measurement terminal of all elements.
5-50
[:INPut]:CURRent:TERMinal[:ALL]
Collectively sets the current measurement terminals of all elements.
5-50
[:INPut]:CURRent:TERMinal:ELEMent<x>
Sets the current measurement terminal of the element or queries the current
setting.
5-50
[:INPut]:FILTer?
Queries all settings related to the filter.
5-50
[:INPut]:FILTer:LINE?
Queries the line filter settings of all elements.
5-50
[:INPut]:FILTer[:LINE][:ALL]
Collectively sets the line filters of all elements.
5-51
[:INPut]:FILTer[:LINE]:ELEMent<x>
Sets the line filter of the element or queries the current setting.
5-51
[:INPut]:FILTer:ZCRoss?
Queries the zero-crossing filter settings of all elements.
5-51
[:INPut]:FILTer:ZCRoss[:ALL]
Collectively sets the zero-crossing filters of all elements.
5-51
[:INPut]:FILTer:ZCRoss:ELEMent<x>
Sets the zero-crossing filter of the element or queries the current setting.
5-51
[:INPut]:MODUle?
Queries the input element type.
5-51
[:INPut]:NULL
Turns ON/OFF the NULL function or queries the current setting.
5-51
[:INPut]:POVer?
Queries the peak over information.
5-51
[:INPut]:SCALing?
Queries all settings related to scaling.
5-51
[:INPut]:SCALing:{PT|CT|SFACtor}?
Queries the scaling constant of all elements.
5-52
[:INPut]:SCALing:{PT|CT|SFACtor}[:ALL]
Collectively sets the scaling constants of all elements.
5-52
[:INPut]:SCALing:{PT|CT|SFACtor}:ELEMent<x>
Sets the scaling constant of the element or queries the current setting.
5-52
[:INPut]:SCALing:STATe?
Queries the scaling ON/OFF states of all elements.
5-52
[:INPut]:SCALing[:STATe][:ALL]
Collectively turns ON/OFF the scaling of all elements.
5-52
[:INPut]:SCALing[:STATe]:ELEMent<x>
Turns ON/OFF the scaling of the element or queries the current setting.
5-52
[:INPut]:SYNChronize?
Queries the synchronization source of all elements.
5-52
[:INPut]:SYNChronize[:ALL]
Collectively sets the synchronization source of all elements.
5-52
[:INPut]:SYNChronize:ELEMent<x>
Sets the synchronization source of the element or queries the current setting. 5-52
[:INPut]:VOLTage?
Queries all settings related to the voltage measurement.
5-52
[:INPut]:VOLTage:AUTO[:ALL]
Collectively turns ON/OFF the voltage auto range of all elements.
5-53
[:INPut]:VOLTage:AUTO:ELEMent<x>
Turns ON/OFF the voltage auto range of the element or queries the current
setting.
5-53
[:INPut]:VOLTage:RANGe?
Queries the voltage range of all elements.
5-53
[:INPut]:VOLTage:RANGe[:ALL]
Collectively sets the voltage range of all elements.
5-53
[:INPut]:VOLTage:RANGe:ELEMent<x>
Sets the voltage range of the element or queries the current setting.
5-53
[:INPut]:WIRing
Sets the wiring system or queries the current setting.
5-53
5.1 Command List
Summary of Contents for wt1600
Page 1: ...Digital Power Meter Communication Interface IM 760101 11E 4th Edition ...
Page 131: ...7 2 IM 760101 11E 7 2 Sample Program Image ...
Page 138: ...Sample Program 7 9 IM 760101 11E 7 7 4 Output of Normal Measurement Data ...
Page 142: ...Sample Program 7 13 IM 760101 11E 7 7 5 Output of Harmonic Measurement Data ...