<6. Menu Overview>
6-2
IM 12Y18A04-01EN
1st Edition : Oct. 04, 2019-00
Temperature Units Menu
Allows selection of units for displaying the temperature readings. Choice of Fahrenheit (°F)
or Celsius (°C).
Method Parameters Menu
Allows configuration of the parameters for method and order of the events for analysis and
calibration. Consult factory before modifying any parameter.
Date and Time Menu
Allows configuration of the date and time format and editing of the current date.
Daylight Saving
Allows configuration of the daylight saving for USA, Europe and custom settings. When
daylight saving is enabled, the system will correct the time based on the settings shown
below the selection.
Recovery After Power Failure Menu
Allows configuration of the instrument after power failure recovery.
Ethernet Parameters Menu
Allows configuration of Ethernet Parameters.
RS-232 Parameters Menu
Allows selection of the BAUD RATE for the RS-232 port. Default setting of 115200 Baud.
Language Menu
Allows configuration of the instrument’s language. Current release is ENGLISH language.
(Consult factory for other languages).
6.2
Measurement Menu
Analyze Once
Allows one manual analysis to be performed. Number of repeats (default = 1) can be edited
in the ANALYSIS MENU. When performing a manual analysis, the user is restricted from
navigating through other menus.
Calibrate
Allows manual calibration to be performed using standard solutions. The slope and intercept
values obtained here may be edited in the CALIBRATION PARAMETERS menu. When
performing a manual calibration, the user is restricted from navigating through other menus.
Validate
Allows manual validation of the instrument with a known sample or standard. When
performing validation, the user is restricted from navigating through other menus.
Clean
Allows manual cleaning of the reaction cell. The parameters set for the manual clean are
also used for auto clean. When performing manual cleaning, the user is restricted from
navigating through other menus.
6.3
View Data and Alarms Menu
Review / Reset Alarms
Allows user to review and selectively reset the faults and alarms triggered during the latest
Analysis/Calibration/Validation/Cleaning cycle performed.
Review Calibration Results
Allows the user to review and print the calibration results from the stored calibration
database, using a selectable time scale. The database holds data from the last 31 days.
Review Analysis Results
Allows the user to review and print the analysis results from the stored analysis database,
using a selectable time scale. The selected results can be displayed in text or graph modes.
The database holds data from the last 31 days.