2-6
<Toc>
<2. Initial Settings>
IM 05D01B02-41E
1st Edition : May 31,2000-00
■
Instrument Input Range Codes
Input
Type
Instrument Input
Range Code
Instrument
Input Range
Measurement Accuracy
OFF (0)
-270.0 to 1370.0
°
C
-450.0 to 2500.0
⬚
F
Set the data item PV Input Type “IN1” to the OFF option to leave the PV input
type undefined.
-270.0 to 1000.0
°
C
-450.0 to 2300.0
⬚
F
K
-200.0 to 500.0
°
C
-200.0 to 1000.0
⬚
F
J
-200.0 to 1200.0
°
C
-300.0 to 2300.0
⬚
F
-270.0 to 400.0
°
C
-450.0 to 750.0
⬚
F
T
0.0 to 400.0
°
C
-200.0 to 750.0
⬚
F
⫾
0.1% of instrument range
⫾
1 digit at 0
°
C or more
⫾
0.2%
⫾
1 digit for temperatures below 0
°
C,
where the accuracy is:
⫾
2% of instrument range
⫾
1
digit for temperatures below -200.0
°
C for a type-K
thermocouple, or
⫾
1% of instrument range
⫾
1 digit for
temperatures below -200.0
°
C for a type-T thermocouple.
B
0.0 to 1800.0
°
C
32 to 3300
⬚
F
⫾
0.15% of instrument range
⫾
1 digit at 400
°
C or more
⫾
5% of instrument range
⫾
1 digit at less than 400
°
C
S
0.0 to 1700.0
°
C
32 to 3100
⬚
F
R
0.0 to 1700.0
°
C
32 to 3100
⬚
F
⫾
0.15% of instrument range
⫾
1 digit
N
-200.0 to 1300.0
°
C
-300.0 to 2400.0
⬚
F
⫾
0.1% of instrument range
⫾
1 digit
⫾
0.25% of instrument range
⫾
1 digit for temperatures
below 0
°
C
E
-270.0 to 1000.0
°
C
-450.0 to 1800.0
⬚
F
L(DIN)
-200.0 to 900.0
°
C
-300.0 to 1600.0
⬚
F
-200.0 to 400.0
°
C
-300.0 to 750.0
⬚
F
U(DIN)
0.0 to 400.0
°
C
-200.0 to 1000.0
⬚
F
⫾
0.1% of instrument range
⫾
1 digit at 0
°
C or more
⫾
0.2%
⫾
1 digit for temperatures below 0
°
C, where the
accuracy is:
⫾
1.5% of instrument range
⫾
1 digit for
temperatures below -200.0
°
C for a type-E thermocouple.
W
0.0 to 2300.0
°
C
32 to 4200
⬚
F
⫾
0.2% of instrument range
⫾
1 digit
Platinel 2
0.0 to 1390.0
°
C
32 to 2500.0
⬚
F
⫾
0.1% of instrument range
⫾
1 digit
PR20-40
0.0 to 1900.0
°
C
32 to 3400
⬚
F
⫾
0.5% of instrument range
⫾
1 digit at 800
°
C or more
No accuracy is guaranteed at less than 800
°
C
Thermocouple
Unspecified
W97Re3-
W75Re25
0.0 to 2000.0
°
C
32 to 3600
⬚
F
⫾
0.2% of instrument range
⫾
1 digit
-200.0 to 500.0
°
C
-300.0 to 1000.0
⬚
F
⫾
0.1% of instrument range
⫾
1 digit (Note 1) (Note 2)
JPt100
-150.00 to 150.00
°
C
-200.0 to 300.0
⬚
F
⫾
0.2% of instrument range
⫾
1 digit (Note 1)
-200.0 to 850.0
°
C
-300.0 to 1560.0
⬚
F
-200.0 to 500.0
°
C
-300.0 to 1000.0
⬚
F
⫾
0.1% of instrument range
⫾
1 digit (Note 1) (Note 2)
RTD
Pt100
-150.00 to 150.00
°
C
-200.0 to 300.0
⬚
F
⫾
0.2% of instrument range
⫾
1 digit (Note 1)
0.4 to 2 V
Standard
signal
1 to 5 V
0 to 2 V
0 to 10 V
0.400 to 2.000 V
1.000 to 5.000 V
0.000 to 2.000 V
0.00 to 10.00 V
-10 to 20 mV
-10.00 to 20.00 mV
DC voltage
0 to 100 mV
0.0 to 100.0 mV
⫾
0.1% of instrument range
⫾
1 digit
Display range is scalable in a range of -19999 to 30000.
Display span is 30000 or less.
typeK1 (1)
typeK2 (2)
typeJ (4)
typeT1 (5)
typeT2 (6)
typeB (7)
typeS (8)
typeR (9)
typeN (10)
typeE (11)
typeL (12)
typeU1 (13)
typeU2 (14)
typeW (15)
Plati2 (16)
PR2040 (17)
W97Re3 (18)
JPt1 (30)
JPt2 (31)
Pt1 (35)
Pt2 (36)
Pt3 (37)
0.4 to 2 V (40)
1 to 5 V (41)
0 to 2 V (50)
0 to 10 V (51)
mV1 (55)
0.00 to 1.25 V
(Note 3)
0.000 to 1.250 V
0.00 to 1.25 V (52)
mV2 (56)
typeK3 (3)
*
Performance in the standard operating conditions (at 23
⫾
2
⬚
C, 55
⫾
10%RH, and 50/60 Hz power frequency)
Note 1: The accuracy is
⫾
0.3
⬚
C of instrument range
⫾
1 digit for a temperature range from 0
⬚
C to 100
⬚
C.
Note 2: The accuracy is
⫾
0.5
⬚
C of instrument range
⫾
1 digit for a temperature range from -100
⬚
C to 200
⬚
C.
Note 3: Not used in single-loop control.
*
To receive a 4-20 mA DC signal, select a standard signal of 1 to 5 V DC and connect it to a 250
⍀
resistor. This resistor
is optional.
Model: X010-250-2 (resistor with M3.5 crimp-on terminal lugs)