Standard Specifications 

 

IM 01G05B03-01E 1st Edition 

*7: The couplant weatherproof type is recommended for 

permanent installation in the outdoor, etc. It is adhesive 
liquefied rubber and tight contacts between transducers 
and pipe surface can be obtained by curing it. It usually 
takes one to three days for complete curing depending on 
the conditions. The operating condition of ambient 
temperature is as below. 
Before and during curing : 0 to +50°C / 32 to 122°F 
After curing : –40 to +180°C / –40 to 356°F 

Accessories (for ultrasonic flowmeter US300FM) 

Model Description 

USPA201 

Pipe mounting fixture(to add the option 
/PMT) 

USPA221 

Blind plug for cable gland port 

USPA231 

Cable gland 

 

Accessories (others) 

Model Description 

USPA401 

RS232 cable (*9) 

USPA402 

RS232 adapter 9/25 (*9) 

USPA411 

Measuring tape 

 
*9: Included in data transfer software US300SA as standard. 
 

Accessories (for transducers US300FT) 

Model Description 

USPA001 

Fixing strap (10 m / 32 ft length) 

USPA002 

Fixing strap (20 m / 65 ft length) 

USPA011 

Fixing clips 
(medium type, for pipe size 40 to 100 mm / 1.5 
to 4 in., set of two clips) 

USPA012 

Fixing clips 
(large type, for pipe size 100 to 6500 mm / 4 to 
255 in., set of two clips) 

USPA021 

Fixing bands 
(only for pipe size 25 to 50 mm / 1 to 2 in.)   

USPA032 

Fixing chains (set of two extensible chains) 
(2 m / 6.5 ft length, equal to 600 mm / 23 in. 
diameter) 

USPA033 

Repair set for fixing chains 

USPA034 

Retaining clips 
(set of two clips, used with fixing chains) 

USPA036 

Fixing chains (set of two extensible chains) 
(0.5 m / 1.6 ft length, equal to 150 mm / 5.9 in. 
diameter) 

USPA037 

Fixing chains (set of two extensible chains) 
(1 m / 3.2 ft length, equal to 300 mm / 11.8 in. 
diameter) 

USPA053 

Mounting fixture short ruler type (for 
transducers medium pipe size type, 
temperature range –30 to +200°C / –22 to 
+392°F, set of two blocks with 120 mm / 4.7 in. 
ruler) 

USPA054 

Mounting fixture standard type (for transducers 
medium pipe size type, temperature range –30 
to +200°C / -22 to +392°F, set of two blocks 
with 330 mm / 13 in. ruler) 

USPA055 

Mounting fixture magnetic general temperature 
type (for transducers medium pipe size type, 
temperature range –30 to +100°C / –22 to 
+212°F, set of two blocks with 330 mm / 13 in. 
ruler) 

USPA057 

Mounting fixture standard type (for transducers 
large or very large pipe size type, temperature 
range –30 to +200°C / –22 to +392°F, set of 
two blocks with 330 mm / 13 in. ruler) 

USPA058

Mounting fixture magnetic general temperature 
type (for transducers large or very large pipe 
size type, temperature range –30 to +100°C /   
–22 to +212°F, set of two blocks with 330 mm / 
13 in. ruler) 

USPA073

Additional magnets for mounting fixture 
magnetic general temperature type 
(for transducers medium pipe size type, 
temperature range –30 to +100°C / –22 to 
+212°F, set of two magnets) 

USPA075

Additional magnets for mounting fixture 
magnetic general temperature type 
(for transducers large or very large pipe size 
type, temperature range –30 to +100°C / –22 to 
+212°F, set of two magnets) 

USPA081

Ruler for mounting fixture 
(marked length 120 mm, equivalent to 4.7 in.) 

USPA082

Ruler for mounting fixture 
(marked length 330 mm, equivalent to 13 in.) 

USPA091

Acoustic couplant general temperature type 
(non-adhesive) 
(100 g, –30 to +130°C) (0.22 lb, –22 to +266°F)

USPA092

Acoustic couplant high temperature type (non-
adhesive) 
(100 g, –30 to +200°C) (0.22 lb, –22 to +392°F)

USPA097

Acoustic couplant weatherproof type (adhesive) 
(*10) 
(100 g, –40 to +180°C) (0.22 lb, –40 to +356°F)

*10:  The operating condition of ambient temperature is as 

below. 
Before and during curing : 0 to +50°C / 32 to 122°F 
After curing : –40 to +180°C / –40 to 356°F

Summary of Contents for US300FM

Page 1: ...ite White Perform soldering Finish the brown cables as well as white cables You do not connect the thin lines to any terminals Brown 12 2 Less than 10mm 12 2 Perform soldering Shield line Cable shield...

Page 2: ...ccurs A Tokuchu request is necessary for Submersible type However the diameter must be over 100 mm Changes to the section 3 5 5 Connection to the Power Supply page 20 AC power supply DC power supply T...

Page 3: ...y this behavior Addition and deletion to the section 4 1 1 Key Operations page 23 and related pages Refer to the following table for the function of corresponding key operations The correct explanatio...

Page 4: ...a wall thickness probe or some other ways and avoid mounting the transducers on such parts Attention Instructions for using Acoustic couplant weatherproof type Shin Etsu Silicone 1 COMPONENT RTV are a...

Page 5: ...the section 14 5 Activation of a Pulse Output page 95 Maximum pulse output rate is 2 pulse per second 20 Set the Pulse Value and the Pulse Width so that the actual maximum flow in the pipe is less th...

Page 6: ...Measuring Input One or two dual Channel A Channel B Current Output One or two Range 4 to 20 mA Load resistance 0 to 500 Note The current outputs may temporarily turn unstable during the power on seque...

Page 7: ...tion only for test service maintenance purposes Time Programmable Measurement Function Automatic start stop of the measurement without human operation using internal clock for specific systems Can be...

Page 8: ...suring data set in graphic format Marker type and color for each line of values selectable Scales for time axis and value axis can be changed from default condition of automatic scaling Graph printing...

Page 9: ...th 4 4 m 14 4 ft cable CH Large High with 4 4 m 14 4 ft cable DG Very large General with 12 m 39 4 ft cable N Always N Fixing band strap and clips 6 B For 25 to 1 400 mm 1 to 55 in Two fixing bands On...

Page 10: ...g fixture short ruler type for transducers medium pipe size type temperature range 30 to 200 C 22 to 392 F set of two blocks with 120 mm 4 7 in ruler USPA054 Mounting fixture standard type for transdu...

Page 11: ...flowmeter US300FM Unit mm inch Transducers US300FT B Transducers US300FT C US300FT D Transducers X m inch Y m inch X Y m inch Weight kg lb US300FT B 2 0 78 7 1 0 39 4 3 0 118 1 0 9 1 98 US300FT C 2 0...

Page 12: ...annel A P1 P1 Current output AR ARS Upstream transducer signal for channel A P2 P2 Current output when specifying two current outputs BV BVS Downstream transducer signal for channel B P3 P3 Frequency...

Reviews: