Standard Specifications
4
IM 01G05B03-01E 1st Edition
Model and Suffix Code
Ultrasonic flowmeter
Model Suffix
code
Specification
US300FM ·····························
Ultrasonic
flowmeter
Output
-A1 ······················
One current output
-A2 ······················
Two current outputs
Power Supply
1 ···················
100 to 230 V AC ±10%
4 ···················
24 V DC ±10%
Input Channel
-1 ················
One input channel
(one-path)
-2 ················
Two input channels
(dual-path)
Electrical connection
-4 ···········
ISO M20 x 1.5, female
Option
/PU1 ····
One binary (pulse or alarm)
output (open-collector) (*1)
/PU2 ····
Two binary (pulse or alarm)
outputs (open-collector) (*1)
/FQ1 ····
Frequency output (open-
collector, 0 to 1 kHz) (*2)
/BGT ····
Tag number on nameplate
(in the nameplate label,
maximum 16 characters)
/SCT ····
Tag number on stainless
steel tag plate (maximum 16
characters)
/PMT ····
Pipe mounting fixture
*1: Option /PU1 and /PU2 are exclusive.
*2: Option /FQ1 is not selectable for two current output (-A2)
models
Connection cable (*8)
Model Suffix
code
Specification
US300FC ····················
Connection cable
Length
-Gxxx ·········
xxx: Cable length 001 to 300 [m]
*8: Two sets of connection cables are necessary when
applying dual channel/path measurement.
Data transfer software
Model Suffix
code
Specification
US300SA ····················
Data transfer software (Windows
version) Including connecting kit
(RS232 cable for connection, RS232
adapter 9/25)
Language
-1 ················
English / German version
00 ·······
Always 00
Transducers (*3)
Model
Suffix code
Specification
US300FT
··························
Transducers for fixed type
Usage (*4)
-G ·····················
General purpose (IP65)
-W ····················
Waterproof (IP67)
Pipe Size /
Fluid
Temperature
(*5)
BG ················
Medium & General (with 3 m /
9.8 ft cable)
BH ················
Medium & High (with 3 m / 9.8 ft
cable)
CG ················
Large & General (with 4.4 m /
14.4 ft cable)
CH ················
Large & High (with 4.4 m / 14.4
ft cable)
DG ················
Very large & General (with 12 m /
39.4 ft cable)
-N ··············
Always N
Fixing band, strap
and clips (*6)
B ············
For 25 to 1,400 mm (1 to 55 in.)
Two fixing bands
One strap of 10 m (32 ft)
length
Two clips of medium type
Two clips of large type
C ············
For 1,400 to 2,800 mm (55 to
110 in.)
One strap of 20 m (65 ft )
length
Two clips of large type
D ············
For 2,800 to 6,500 mm (110 to
255 in.)
Two straps of 20 m (65 ft)
length
Two clips of large type
N ············
None
Acoustic couplant
(*7)
G ·········
General temperature type (non-
adhesive, –30 to +130°C / –22
to +266°F)
H ·········
High temperature type (non-
adhesive, –30 to +200°C / –22
to +392°F)
R ·········
Weatherproof type (adhesive,
–40 to +180°C / –40 to +356°F)
N ·········
None
Option
/TTP ···
Transducer tag plate (maximum
16 characters)
*3: Two sets of transducers are necessary when applying dual
channel/path measurement.
*4: A Tokuchu request is necessary when transducers are
installed where condensation occurs. However the pipe
size must be over 100 mm (Large type or Very large type).
*5: The alphabetic characters in the suffix code represent pipe
sizes and fluid temperature ranges are below.
B: Medium type (25 to 400 mm / 1 to 16 in.)
C: Large type (100 to 2,500 mm / 4 to 98 in.)
D: Very large type (2,000 to 6,500 mm / 78 to 255 in.)
G: General temperature (–30 to +130°C / –22 to +266°F)
H: High temperature (–30 to +200°C / –22 to +392°F)
*6: When the pipe size is less than 50 mm (2 in.), select
N(None) here first and order separately one each of
USPA053 mounting fixture short ruler type, USPA036
fixing chains (0.5 m/1.6 ft length), and USPA097 couplant
weatherproof type. It will avoid any stress that could be
caused by expansion of the pipe after installation. The
couplant weatherproof type can be specified by the code R