Remote control function (/R1 option)
Item
Description
Reference
Section
Remote control function (/R1 option)
• Assign functions to the remote control input terminals
7.18
Use
Remote
in Basic Setting mode to set the function to be assigned to the remote control input
terminal.
• Secondary chart speed
6.9
If “chart speed switching” is assigned, use
Aux > Chart 2
in Setting mode to set the secondary
chart speed.
• Switching between start printout and start printout 2 and between end printout and end printout
2 (/BT1 option)
If BatchCMT switch is assigned
Use
Batch > Dual comment
in Basic Setting mode to enable or disable start printout 2 and end
printout 2.
7.24
If Use is selected, set
Batch > Detail > Start2
and
End2
in Setting mode.
6.14
If Not is selected, the
Batch > Detail > Start2
and
End2
items in Setting mode do not appear.
Calibration Correction (/CC1 Option)
Item
Description
Reference
Section
Calibration correction function
Use
Personalize > Add function > Calibration
in Basic Setting mode and select Use or Not.
7.15
If Use is selected,
• Use
Calibration
in Basic Setting mode to set the correction mode and the number of calibration
points.
7.23
• Use
Calibration
in Setting mode to set the measured value and correction value for each
channel.
6.13
If Not is selected, the
Calibration
item does not appear.
Header Printout (/BT1 Option)
Item
Description
Reference
Section
Setting start printout and end printout
Use
Batch
in Basic Setting mode to set whether to use the start printout and end printout. If Use is
selected, select a Lot No. from 4 digits, 6 digits, or OFF.
7.24
If Use is selected,
Use
Batch > Batch No.
in Setting mode to set the batch number.
6.14
Use
Batch > Lot No.
in Setting mode to set the lot number.
Use
Batch > Detail > Start, End
in Setting mode.
If Not is selected, the
Batch > Lot No.
item in Basic Setting mode and the Batch item in Setting
mode do not appear.
Switch between start printout and start printout 2 and between end printout and end printout 2 (/R1 option)
• Switch settings
Assign “BatchCMT switch” to the remote control input terminal.
7.18
Use
Batch > Dual comment
in Basic Setting mode to set whether to use start printout 2 and end
printout 2.
7.24
If Use is selected, set
Batch > Detail > Start2
and
End2
in Setting mode.
6.14
If Not is selected, the
Batch > Detail > Start2
and
End2
items in Setting mode do not appear.
• Executing the switch
1.4
The switch occurs according to the status of the “BatchCMT switch” signal when “Record On/Off”
or “Priority R_RCD” signal assigned to the remote control input terminal rises or falls.
Printout of messages including measured/computed values
• Setting message strings
6.8
Use
Aux > Message
in Setting mode to enter the message to print out.
• Setting the message format
Use
Batch > MSG format
in Basic Setting mode and select whether to use the message format. 7.24
If Use is selected, use
Batch > MSG format > Message No.
in Setting mode to set the message
format.
6.15
If Not is selected, the
Batch > MSG format
item does not appear.
• Executing message printout
3.10
Use
Func > Message
in Operation mode to execute the message printout.
1.10 Function Setup Guide