1.10 Function Setup Guide
This section explains the settings necessary to use various functions of the recorder.
Read the section corresponding to the function you wish to use.
Note
This section contains all the settings related to each item. If the desired setting is the same as
the default value, you do not have to set it.
Item
Description
Reference
Section
Date/Time setting
Use
Clock
in Setting mode.
5.5
DST
Sets the date/time for switching between DST and standard time using
Aux > DST
in
Setting mode.
6.16
Setting initialization
Use
Initialize
in Basic Setting mode to initialize the settings of Setting mode and Basic
Setting mode to their default values.
7.17
Measuring input functions
Item
Description
Reference
Section
Range and span of the TC, RTD, or DC voltage
Use
Range
in Setting mode.
5.1
1-5V
• Range, span, and scale
5.1
Use
Range
in Setting mode.
• Unit
5.3
Use
Unit
in setting mode to set the unit after scaling.
• Low-cut
7.15
Use
Personalize > Add function > 1-5V low-cut
in Basic Setting mode and select
Use or Not.
5.1
If Use is selected, turn On/Off
Low-cut
using
Range
in Setting mode.
If Not is selected, the
Low-cut
item does not appear in the
Range
setting.
Scaling
• Range, span, and scale
5.1
Use
Range
in Setting mode.
• Unit
5.3
Use
Unit
in setting mode to set the unit after scaling.
Square Root Computation • Range, span, and scale
5.1
Use
Range
in Setting mode.
• Unit
5.3
Use
Unit
in setting mode to set the unit after scaling.
• Low-cut
7.15
Use
Personalize > Add function > SQRT low-cut
in Basic Setting mode and select
Use or Not.
If Use is selected, set the
Low-cut point
using
Range
in Setting mode.
5.1
If Not is selected, the
Low-cut
item does not appear in the
Range
setting.
Unused channels
Use
Range > Skip
in Setting mode to disable the trend recording (dot model) and
periodic printout of the target channel.
5.1
Bias
Use
Personalize > Add function > Bias
in Basic Setting mode and select Use or Not. 7.15
If Use is selected, set the bias value that is added to the input using
Bias
in Setting
mode. If Not is selected, the
Bias
item does not appear.
6.12
Burnout detection function (TC input and 1-5V input)
7.3
Use
Burnout
in Basic Setting mode to set the burnout detection function for each
channel.
RJC of TC input
Use
RJC
in Basic Setting mode to select whether to use the internal RJC function or an
external RJC function.
7.4
Filter (pen model)
Use
Filter
in Basic Setting mode and select Use or Not.
7.12
If Use is selected, set the filter time constant using
Aux > Filter
in Setting mode.
6.2
If Not is selected, the
Aux > Filter
item does not appear.
Summary of Contents for mR10000 436101
Page 2: ......
Page 14: ...Blank ...
Page 18: ...Blank ...
Page 58: ...Blank ...
Page 72: ...Blank ...
Page 92: ...Blank ...
Page 220: ...Blank ...
Page 268: ...Blank ...