3-34
IM 34M06H43-02E 2nd Edition : Sep.30, 2019-00
Table 3.10.2 Restrictions on Setup Values
Item
Normal Mode
High-Speed Mode
Link Relay
Link Register
Link Relay
Link Register
Top Address
L0001 to L2033
On 16-point basis
*1
W0001 to W2048
On 1-point basis
L0001 to L1009
On 16-point basis
*1
W0001 to W1024
On 1-point basis
Size
0 to 2048 points
On 16-point basis
*2
0 to 2048 points
On 1-point basis
0 to 1024 points
On 16-point basis
*2
0 to 1024 points
On 1-point basis
*1:
Specify a 16-point basis value, such as L0001, L0017, or L0033.
*2:
Specify a 16-point basis value, such as 0, 16, or 32.
CAUTION
Link data cannot be written to a stations whose the top address and size area are
not set, or to stations whose size is set to 0. These stations become read-only
station.
Always perform registration after setup is completed.
Batch registration (of all 32 stations)
This registers the link information defined for all the 32 stations of the FA Link
module.
Step 1
Click [Register Module] on the window displaying the link information
read from a module or from a link information file.
Figure 3.10.8 Batch registration (of all 32 stations) to the FA Link module 1
F03A9.VSD