6-15
IM80B80T10E
21th Edition : Jul.1,2007-00
< 6.INSTALLATION >
F 1
F 2
DISPL
PREV MODE
F 1
F 2
DISPL
PREV MODE
MAINT
MAINT
F 1
F 2
DISPL
PREV MODE
MAINT
a.
-5-7
-5-8
-5-71
d.
F 1
F 2
DISPL
PREV MODE
MAINT
b.
F 1
F 2
DISPL
PREV MODE
MAINT
c.
5 kt data
10kt data
Press the
‘ENT’ key.
Enter 0,5,3,
and 6 in this
order from
the numeric
keypad.
At
-5-7
, press the
F 1
key to select the linearizer handling mode. The display then changes
to that marked
a
.
While the display is at
a
to
d
, pressing the
F 1
key (NXT) or
F 2
key (BFR) changes the
displayed items in the order shown in the figure below. (The number at the beginning of the top line
of the display means the log speed level in the linearizer table.)
F 1
F 2
NXT
BFR
5 kt
Data on the table
10 kt
Data on the table
15 kt
Data on the table
60 kt
Data on the table
65 kt
Data on the table
key
key
(i) Modification of data
Press either the
F 1
key (NXT) or
F 2
key (BFR) until the data to be modified appear on
the display. Enter a new value using the numeric keypad. Confirm the entered value, and then
press the
ENT
key. Modification of the data has now been completed.
(ii) Confirmation of data
To confirm (refer to) data, press either the
F 1
key (NXT) or
F 2
key (BFR) until the required
data appear on the display.