6-2
IM80B80T10E
21th Edition : Jul.1,2007-00
< 6.INSTALLATION >
6.2
Response-speed Setting
Determine the response speed according to the performance of the ship. The relationship between
the set value and actual output response is as follows :
10
0
20
30
40
50
50
100
(%)
(sec)
(1)
(2)
(3)
(4)
Time
Output response
(1) : Set value = 1
(2) : Set value = 2
(3) : Set value = 4
(4) : Set value = 10
Default
: 5
Recommended values
For ships at 20 kt or 25 kt. : 5
For ships at 35 kt or 40 kt. : 3
For ships at 50 kt or 65 kt. : 2
Press the
F 1
key at
-5-4
to select the re-
sponse speed setting .The display then changes
to that marked
a
. Here, the previously-set value is
flickering on the display.
The operation flow on the left gives an example of
setting '20'. To do this, first enter
2
and
0
using the numeric keypad. Confirm that the values
has just been entered, and then press the
ENT
key. This stops the flickering (see the display
marked
c
), and completes the setting of the new
value (at time constant 20 seconds).
Setting range : 1 to 20
F 1
F 2
DISPL
PREV MODE
F 1
F 2
DISPL
PREV MODE
MAINT
MAINT
F 1
F 2
DISPL
PREV MODE
MAINT
F 1
F 2
DISPL
PREV MODE
MAINT
a.
-5-4
-5-5
-5-41
b.
c.
Previously-set value
Press the ‘ENT’ key
Enter 2 and 0 in this
order from the
numeric keypad.
F 1
F 2
DISPL
PREV MODE
F 1
F 2
DISPL
PREV MODE
MAINT
MAINT
F 1
F 2
DISPL
PREV MODE
MAINT
F 1
F 2
DISPL
PREV MODE
MAINT
a.
-5-4
-5-5
-5-41
b.
c.
Previously-set value
Press the ‘ENT’ key
Enter 2 and 0 in this
order from the
numeric keypad.