6-3
IM80B80T10E
21th Edition : Jul.1,2007-00
< 6.INSTALLATION >
6.3
Parameter Settings
6.3.1
Master Indicator
1
2
3
4
5
6
7
8
OFF
ON
Mode Setting switch
(The figure on the left is the factory setting.)
� Mode setting ..... Dip switch (DSW1)
Various parameters can be set with a combination of the on (right) and off (left) positions of the eight
bits (No.1 to No.8) of the dip switch.
� Master indicator
(1) No.1 ..... Not used.
(2) No.2 ..... Not used.
(3) No.3 ..... Not used.
(4) No.4 ..... Baud rate
ON
..... 9600 bps
OFF
..... 4800 bps (factory setting)
(5) No.5 ..... Not used.
(6) No.6 ..... Not used.
(7) No.7 ..... Not used.
(8) No.8 .....LR221 Connection
ON
..... no connection
OFF
..... connection (factory setting)
6.3.2
Analog Indicator
(1) No.1 / No.2 / No.3 ..... Speed rage setting (DSW1)
Various speed ranges can be set based on the combinations of the on and off positions of these
switch bits as shown below.
- 4kt to 20 kt
- 5 kt to 25 kt
- 7 kt to 35 kt
- 8 kt to 40 kt
-10 kt to 50 kt
-13 kt to 65 kt
1
2
3
4
5
6
7
8
O
N
1
2
3
O
N
1
2
3
O
N
1
2
3
O
N
1
2
3
O
N
1
2
3
O
N
(2) No.4 ..... baud rate
ON
.....9600 bps
OFF
..... 4800 bps (factory setting)
(3) No.5 .... Not used.
(4) No.6 ..... Selection of single -axis or dual-axis
ON
..... single-axis
OFF
..... dual-axis