![YOKOGAWA DpharpEJX vigilantplant EJX110 User Manual Download Page 47](http://html1.mh-extra.com/html/yokogawa/dpharpejx-vigilantplant-ejx110/dpharpejx-vigilantplant-ejx110_user-manual_3738051047.webp)
IM 01C25B01-01E
9-2
9. GENERAL SPECIFICATIONS
EJX130A
Capsule
Pressure
M, H
32 MPa (4500 psi)
EJX310A
Capsule
Pressure
M
130 kPa abs (38 inHg abs)
A
3.5 MPa abs (500 psia)
B
16 MPa abs (2300 psia)
EJX430A
Capsule
Pressure
H
500 kPa (2000 inH2O)
A
3.5 MPa (500 psi)
B
16 MPa (2300 psi)
EJX440A
Capsule
Pressure
C
32 MPa (4500 psi)
D
50 MPa (7200 psi)
Minimum Pressure Limit
See graph below
EJX110A, EJX130A, EJX430A, EJX440A
Atmospheric
pressure
-40
(-40)
0
(32)
40
(104)
80
(176)
120
(248)
1(0.14)
2.7(0.38)
10(1.4)
(psi abs)
100(14.5)
Process temperature
C (
F)
Working
pressure
kPa abs
Applicable range
F0901.EPS
EJX310A
-40
(-40)
0
(32)
40
(104)
80
(176)
120 (248)
0.1(0.75)
0.13(1)
1(7.5)
100(750)
10(75)
2.7(20)
0.46
(3.45)
0.01(0.075)
0.013(0.1)
85
(185)
(mmHg abs)
Working
pressure
kPa abs
Applicable range
Process temperature
C(
F)
M,A and B capsule
L capsule
F0902.EPS
Figure 9.1
Working Pressure and Process Temperature
Maximum Over Pressure
EJX310A
Capsule
Pressure
M
500 kPa abs (72 psia)
A
16 Mpa abs (2300 psia)
B
25 MPa abs (3600 psia)
EJX430A
Capsule
Pressure
H, A
16 MPa (2300 psi)
B
25 MPa (3600 psi)
EJX440A
Capsule
Pressure
C
48 MPa (6750 psi)
D
75 MPa (10800 psi)