<2. Handling Cautions>
23
IM 01C25A01-01E
(5) Maintenance and Repair
WARNING
The instrument modification or parts replacement by
other than an authorized Representative of Yokogawa
Electric Corporation is prohibited and will void the
certification.
(6) Name Plate
F0215-1.ai
Name plate
Tag plate for flameproof type
D
WARNING
No. KEMA 07ATEX0109 X
Ex d IIC T6...T4 Gb, Ex tb IIIC T85°C Db
Enlcosure : IP66/IP67
TEMP. CLASS
T6
T5
T4
PROCESS TEMP.(Tp.) -50 TO 85
100 120 °C
Tamb. (for GAS)
-50 TO 75
80
75 °C
T85°C(Tamb.: -30(-15) TO 75°C, Tp.:-30(-15) TO 85°C)(for Dust)
AFTER DE-ENERGIZING, DELAY 5 MINUTES BEFORE
OPENING.
WHEN THE AMBIENT TEMP.
≥
65°C, USE THE
HEAT-RESISTING CABLE & CABLE GLAND
≥ 90°C
POTENTIAL ELECTROSTATIC CHARGING HAZARD -SEE THE USER’S MANUAL
*3
F0215-2.ai
Tag plate for intrinsically safe Ex ia for HART/BRAIN
WARNING
D
No. DEKRA 11ATEX 0228 X
Ex ia IIC T4 Ga Ta: -50 TO 60°C
Ex ia IIIC T85°C T100°C T120°C Db Ta:-30(-15) TO 60°C
IP66/IP67
MAX. PROCESS TEMP.(Tp.) 120°C
T85°C(Tp.:80°C), T100°C(Tp.:100°C), T120°C(Tp.:120°C)
Ui=30V, Ii=200mA , Pi=0.9W, Ci=27.6nF, Li=0µH
POTENTIAL ELECTROSTATIC
CHARGING HAZARD
- SEE USER’S MANUAL
[Except for EJX9
0A]
Tag plate for intrinsically safe Ex ic for HART/BRAIN
WARNING
Ex ic IIC T4 Gc
IP66
Tamb -30(-15) TO 60°C
MAX. PROCESS TEMP. 120°C
Ui=30V, Ci=27.6nF, Li=0µH
POTENTIAL ELECTROSTATIC
CHARGING HAZARD
- SEE USER’S MANUAL
*3
F0215-3.ai
Tag plate for intrinsically safe Ex ia for Fieldbus
No. KEMA 06ATEX0278 X
Ex ia IIC/IIB T4 Ga Ta: -40 to 60°C
Ex ia IIIC T85°C T100°C T120°C Db Ta: -30(-15) to 60°C
MAX PROCESS TEMP.(Tp.): 120°C
T85°C (Tp.: 80°C), T100°C (Tp.: 100°C), T120°C (Tp.: 120°C)
ENCLOSURE: IP66/IP67
Supply circuit
FISCO field device(IIC/IIB)
Entity Parameter Ui=24V, Ii=250mA, Pi=1.2W, Ci=3.52nF, Li=0µH
Sensor circuit
Uo=7.63V, Io=3.85mA, Po=0.008W, Co=4.8uF, Lo=100mH
POTENTIAL ELECTROSTATIC CHARGING HAZARD-SEE USER'S MANUAL.
*3
[EJX9
0A]
Tag plate for intrinsically safe Ex ia for Fieldbus
WARNING
No. KEMA 04ATEX1116 X
Ex ia IIC/IIB T4 Ga Ta:-40 to 60°C
Ex ia IIIC T85°C T100°C T120°C Db Ta:-30(-15) to 60°C
MAX PROCESS TEMP.(Tp.):120°C
T85°C(Tp.:80°C), T100°C(Tp.:100°C), T120°C(Tp.:120°C)
Enclosure: IP66/IP67
FISCO field device(IIC/IIB)
Entity parameters Ui=24V, Ii=250mA, Pi=1.2W, Ci=3.52nF, Li=0μH
WARNING
POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE USER'S MANUAL.
D
Tag plate for intrinsically safe Ex ic for Fieldbus
Ex ic IIC T4 Gc
IP66
Tamb -30(-15) TO 60°C
MAX. PROCESS TEMP. 120°C
Ui=32V, Ci=3.52nF, Li=0µH
POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE USER'S MANUAL.
*3
MODEL: Specified model code.
STYLE: Style code.
SUFFIX: Specified suffix code.
SUPPLY: Supply voltage.
OUTPUT: Output signal.
MWP: Maximum working pressure.
CAL RNG: Specified calibration range.
NO.: Serial number and year of production
*1
.
TOKYO 180-8750 JAPAN:
The manufacturer name and the address
*2
.
*1: The first number in the second block of “NO.” column
is the last one number of the production year.
second block
NO. 91K819857 132 7
The year 2011
*2: “180-8750” is a zip code which represents the
following address.
2-9-32 Nakacho, Musashino-shi, Tokyo Japan