<2. Handling Cautions>
9
IM 01C25A01-01E
b. FM Intrinsically Safe/Nonincendive for
Fieldbus Type (Except for EJX9
0A)
EJX/EJA-E Series pressure transmitters with optional
code /FS15 are applicable for use in hazardous
locations.
Note 1.
• Applicable Standard:
Class 3600:2011, Class 3610:2010,
Class 3611:2004, Class 3810:2005
ANSI/ISA-60079-0:2009, ANSI/ISA-60079-11:2009
NEMA 250:1991
• Rating
Intrinsically Safe with Entity/FISCO for
Class I, II, III Division 1,
Groups A, B, C, D, E, F, G T4
Class I Zone 0 AEx ia IIC T4
Nonincendive field wiring/FNICO for
Class I, II Division 2
Groups A, B, C, D, F, G T4
Class III Division 1 T4
Class I, Zone 2 Group IIC T4
• Ambient temperature: –40 to 60°C
• Enclosure: Type 4X
• Electrical Connection:
1/2 NPT female, M20 female
Note 2. Installation
Installation should be in accordance with Control
Drawing IFM024-A12.