<8. Setting Parameters>
8-7
IM 01C27C01-01EN
(2) Menu Tree
The menu tree of the device configuration tool of our recommendation is shown below. Refer to Subsection 9.2
“Calibration Instruments Selection” for the device configuration tool of our recommendation.
• UAPMO
• TRANSDUCER
• AI1 DP
• AI2 SP
• AI3 Temp
• Device Configuration
• Diagnostic
• Process Variable
(Device Configuration)
Menu (Online)
F0803-1.ai
• Configure/Setup
(UAPMO)
• UAP Option
• Hardware Write Protect
• Static Revision
• Reset Energy Left
• Radio Silence
• Energy Harvest Type
(Configuration)
• Version Revision
• CTS Version
• ITS Version
• Identification Number
(Identification)
• Configure/Setup
(AI1 DP)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Block Mode)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Configuration)
• Block Mode
• Cal Cmd *
• Cal Status
• Calibration Highest Point
• Set Calibration Highest Point *
• Calibration Lowest Point
• Set Calibration Lowest Point *
• Calibration Minimum Span
• External Zero Trim *
(Calibration)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Block Mode)
• Upper Limit
• Lower Limit
• PV Range *
• Linerization Type *
• Flow Constant *
• Lower Cutoff
• Low Cut Mode *
• H/L Swap *
• T Zero Cmp *
• Temp Zero *
• Temp Select *
(Others)
• PV Range.EU at 100% *
• PV Range.EU at 0% *
• PV Range.Units Index *
• PV Range.Decimal*
(PV Range)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Block Mode)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(Scale)
• Tag Description
(Block Info)
• Configure/Setup
(TRANSDUCER)
• Auto Recovery
• Model
• Sensor Serial Number
• Measurement Rate
• Measurement Mode
• Wireless Status
• Display Selection
• LCD Mode
• Special Order ID
• Unit Sel1
• Display Unit1
• LCD Intermittent Time
• XD Filter
• EJX Key
• Test Key 1
• Test Key 2
• Test Key 3
(Configuration/Calibration)
• Tag Description
(Block Info)
• Special Cmd
(Others)
• Other Faults Alert
• Faults Non-compliance
Alert
• Faults Process Influence
Alert
• Simulation Active Alert
• Soft Update Incomplete
Alert
• Power Low Alert
• Power Critical Low Alert
• Fault Prediction Alert
• Environmental
Conditions Alert
• Outside Sensor Limits
Alert
• Out of Service Alert
• Calibration Problem
Alert
• Faults Sensor or
Actuator Alert
• Faults Electronics Alert
(Alerts)
*:
When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service).