10-6
IM AQ1200-01EN
10.3 Selecting and Saving Core and Tape Numbers
Delete Data Screen
No. 1, 2, and 3
Core no.
Deletes the data of all the
selected cores
Deletes all the core data
Use the rotary knob and the arrow
keys to select a core number.
If you delete data, the Save
Data menu is displayed.
Detailed Setup Screen
Press
SETUP
and then the
Save Data
soft key to display the following screen.
Set the starting core number (1 to 9900).
Set the number of fibers or tapes (up to 100 fibers when
Tape no. Type is set to Off, up to 50 tapes when Tape no.
Type is set to a-b(2), ..., up to 12 tapes when Tape no. Type
is set to a-h(8)).
Set the tape number type (Off, a-b(2), a-c(3), a-d(4), a-e(5),
a-f(6), a-g(7), a-h(8)).
Saving Data to a File
Press
SETUP
and then the
File
soft key to display the file save screen. Follow the procedure in
section 16.2 to save the data.
Explanation
The PON power meter is only available on models with -PPM suffix codes.
You can specify core numbers and tape number types and save data (measurement conditions and
measured values) to the AQ1100 internal memory. You can also save the data to a file.
Displayed List
You can set the list to show to one of the following options. The list display format changes depending
on the starting core number, tape number type, and number of fibers (or tapes) that you set in the
detailed setup screen.
Core List
A list of core numbers and the saved data of the highlighted core number are displayed.
List
The core numbers and saved data are displayed.