IM 01E21A03-01EN

1

 

 

<1.  Introduction>

1

1.   Introduction

This manual provides the basic guidelines for 

explosion protection type of ADMAG TI (Total 

Insight) Series AXG magnetic flowmeters.

For the items which are not covered in this manual, 

read the applicable user’s manuals and general 

specifications as listed in IM 01E21A21-01Z1 (Read 

Me First). These documents can be downloaded 

from the website of YOKOGAWA. To ensure correct 

use of the product, read these manuals thoroughly 

and fully understand how to operate the product 

before maintaining it. For method of checking 

the model and specifications, read the applicable 

general specifications in IM 01E21A21-01Z1 (Read 

Me First).

Website address: http://www.yokogawa.com/fld/doc/

These manuals can be downloaded from the

website of YOKOGAWA or purchased from the

YOKOGAWA representatives.

NOTE

When describing the model name like “AXG###” 

in this manual, “###” means any of the following.

For AXG###:

002, 005, 010, 015, 025, 032, 040, 050, 065, 

080, 100, 125, 150, 200, 250, 300, 350, 400

  Precautions Related to the Protection, 

Safety, and Alteration of the Product

The following safety symbol marks are used in this 

manual and product.

WARNING

 

A WARNING sign denotes a hazard. It calls 

attention to procedure, practice, condition or the 

like, which, if not correctly performed or adhered 

to, could result in injury or death of personnel.

CAUTION

A CAUTION sign denotes a hazard. It calls 

attention to procedure, practice, condition or the 

like, which, if not correctly performed or adhered 

to, could result in damage to or destruction of 

part or the entire product.

IMPORTANT

An IMPORTANT sign denotes that attention 

is required to avoid damage to the product or 

system failure.

NOTE

A NOTE sign denotes information necessary 

for essential understanding of operation and 

features.

The following symbols are used in the product and 

the manual to indicate the accompanying safety 

precautions:

Protective grounding terminal

Functional grounding terminal (This terminal should 

not be used as a protective grounding terminal.)
Alternating current
Direct current
Caution

This symbol indicates that the operator must refer to 

an explanation in the user’s manual in order to avoid 

the risk of injury or death of personnel or damage to 

the product.

• 

For the protection and safe use of the product 

and the system in which this product is 

incorporated, be sure to follow the instructions 

and precautions on safety that is stated in user's 

manual as listed in IM 01E21A21-01Z1 (Read 

Me First) whenever you handle the product. 

Take special note that if you handle the product 

in a manner that violated these instructions, 

the protection functionality of the product 

may be damaged or impaired. In such cases, 

YOKOGAWA does not guarantee the quality, 

performance, function, and safety of product.

•  Do not modify this product.

•  The product should be disposed of in 

accordance with local and national legislation/

regulations.

Summary of Contents for ADMAG TI Series

Page 1: ...ADMAG TI Series AXG Magnetic Flowmeter FM USA Explosion Protection Type IM 01E21A03 01EN 1st Edition IM 01E21A03 01EN User s Manual ...

Page 2: ... Edition 1st Edition Oct 2019 KP All right Reserved Copyright 2019 Yokogawa Electric Corporation Contents 1 Introduction 1 2 Explosion Protection Type 3 2 1 Technical Data 3 2 2 Cable Entry 7 2 3 Installation 7 2 4 Operation 12 2 5 Maintenance and Repair 12 2 6 Specific Condition of Use 12 Revision Information ...

Page 3: ...N A CAUTION sign denotes a hazard It calls attention to procedure practice condition or the like which if not correctly performed or adhered to could result in damage to or destruction of part or the entire product IMPORTANT An IMPORTANT sign denotes that attention is required to avoid damage to the product or system failure NOTE A NOTE sign denotes information necessary for essential understandin...

Page 4: ...neers responsible for installation and wiring of the instrument To ensure correct use read this manual and the applicable user s manuals as listed in IM 01E21A21 01Z1 Read Me First thoroughly before starting operation Read the general specifications as listed in IM 01E21A21 01Z1 Read Me First for its specification Trademark All the brands or names of Yokogawa Electric s products used in this manua...

Page 5: ... after tightening the cover 2 1 Technical Data Applicable Standard FM 3600 FM3610 FM3615 FM3616 FM3810 ANSI UL UL 50E NEMA 250 ANSI UL 60079 0 ANSI UL 60079 7 ANSI UL 60079 11 ANSI UL 60079 18 ANSI UL 61010 1 ANSI UL 61010 2 30 Certificate FM 17US0140X Integral Flowmeter Explosionproof Explosion Protection Code FF2 Type of Protection CL I II III GPABCDEFG IS CL I GPABCD T6 T3 Enclosure Type 4X Amb...

Page 6: ...Ambient Temperature 40 C to 60 C Temperature class T6 Power Supply 100 to 240 Va c 50 60 Hz 100 to 120 Vd c 24 Va c 50 60 Hz 24 Vd c Control Drawing DIE016 A92 Table 2 1 Temperature Ratings Model Size Process Connection Lining Temperature Table Integral Flowmeter Remote Sensor AXG002 AXG005 AXG010 AXG015 2 5 to 15 mm 0 1 to 0 5 in Wafer Flange PFA Lining Table A Table C AXG025 AXG032 AXG040 AXG050...

Page 7: ... C T3 T150 C 40 C to 150 C D 40 C to 45 C T6 T75 C 40 C to 50 C 40 C to 60 C T5 T90 C 40 C to 75 C T4 T120 C 40 C to 120 C T3 T150 C 40 C to 150 C E 10 C to 45 C T6 T75 C 10 C to 50 C 10 C to 60 C T5 T90 C 10 C to 75 C T4 T120 C 10 C to 120 C T3 T130 C 10 C to 130 C F 10 C to 45 C T6 T75 C 10 C to 50 C 10 C to 60 C T5 T90 C 10 C to 75 C T4 T120 C 10 C to 120 C T3 T150 C 10 C to 150 C G 10 C to 60 ...

Page 8: ... to 8 in flange type wafer type 250 to 300 mm 10 to 12 in flange type 350 to 400 mm 14 to 16 in flange type F0202 ai 1 1 For wafer types of 150 to 200 mm 6 to 8 in or carbon steel flange types process connection code C of 50 to 400 mm 2 to 16 in the minimum temperature is 10 C 14 F PFA Lining Remote Sensor and Integral Flowmeter high pressure type ASME Class 600 flange F0203 ai Pressure MPa psi Te...

Page 9: ...ring shall be in conduit as follows SEALALL CONDUITS WITHIN 18 INCHES In order to prevent the grounding conductor from loosening the conductor must be secured to the terminal tightening the screw with appropriate torque Care must be taken not to twist the conductor Warning In cases where the ambient temperature exceeds 50 C use external heat resistant wiring with a maximum allowable temperature of...

Page 10: ...IM 01E21A03 01EN 8 2 Explosion Protection Type 8 Read the Control Drawing All wiring shall comply with local installation requirements Integral Type Flowmeter Explosion Protection Code FJ2 F0213 ai ...

Page 11: ...IM 01E21A03 01EN 9 2 Explosion Protection Type 9 Remote Type Flowmeter Explosion Protection Code FJ2 F0214 ai ...

Page 12: ...IM 01E21A03 01EN 10 2 Explosion Protection Type 10 Integral Type Flowmeter Explosion Protection Code FT2 F0215 ai ...

Page 13: ...IM 01E21A03 01EN 11 2 Explosion Protection Type 11 Remote Type Flowmeter Explosion Protection Code FT2 F0216 ai ...

Page 14: ...orporation can repair the equipment 2 6 Specific Condition of Use In the case the electrodes and or grounding rings are made of titanium the sensor should be kept away from impacts and frictions in hazardous locations Electrostatic charges on the non metallic parts excluding glass parts or coated parts of the product shall be avoided The applicable temperature class ambient temperature range and p...

Page 15: ... 01E21A03 01EN 13 Revision Information Title ADMAG TI Series AXG Magnetic Flowmeter FM USA Explosion Protection Type Manual No IM 01E21A03 01EN Edition Date Page Revised Item 1st Oct 2019 New Publication ...

Reviews: