YOKOGAWA ADMAG TI Series User Manual Download Page 6

IM 01E21A03-01EN

4

 

<2. Explosion Protection Type>

4

Remote Sensor 

Explosionproof

(Explosion Protection Code: FF2)

•  Type of Protection:

 

CL I/II/III GP ABCDEFG  

IS CL I GP ABCD  

T6...T3 

•  Enclosure: Type 4X

•  Ambient Temperature: 

 

See Table 2.1 and Table 2.2.

•  Process Temperature: 

 

See Table 2.1 and Table 2.2.

•  Um: 250 V

•  Maximum Working Pressure: 

 

Read “Fluid Temperature and Pressure”

Remote Transmitter 

Explosionproof

(Explosion Protection Code: FF2)

•  Type of Protection:

 

CL I/II/III GP ABCDEFG 

•  Enclosure: Type 4X

•  Ambient Temperature: –40°C to +60°C

•  Temperature class: T6

•  Power Supply:

 

100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. 

24 Va.c. (50/60 Hz) / 24 Vd.c.

•  Current I/O: 4 to 20 mA, 32 Vd.c. max.

•  Digital I/O: 30 Vd.c. max., 200 mA max.

•  Fieldbus I/O: 32 Vd.c. max., 15 mA max. 

Explosionproof with Output IS Circuit

 

(Explosion Protection Code: FJ2 and FT2)

•  Type of Protection

 

CL I/II/III GP ABCDEFG  

AIS CL I/II/III GP ABCDEFG

•  Enclosure: Type 4X

•  Ambient Temperature: –40°C to +60°C

•  Temperature class: T6

•  Power Supply:

 

100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. 

24 Va.c. (50/60 Hz) / 24 Vd.c.

•  Control Drawing: DIE016-A92

Table 2.1  

Temperature Ratings

Model

Size

Process 

Connection

Lining

Temperature Table

Integral 

Flowmeter

Remote  

Sensor

AXG002, AXG005,

AXG010, AXG015

2.5 to 15 mm

(0.1 to 0.5 in.)

Wafer, Flange

PFA Lining

Table A

Table C

AXG025, AXG032,

AXG040, AXG050,

AXG065, AXG080,

AXG100, AXG125 

25 to 125 mm

(1 to 5 in.)

Wafer, Flange

PFA Lining

Table B

[Table J]*

1

Table D

[Table J]*

1

AXG150, AXG200,

AXG250, AXG300,

AXG350, AXG400

150 to 400 mm

(6 to 16 in.)

Wafer, Flange

PFA Lining

Table A

Table C

AXG015, AXG025,

AXG032, AXG040,

AXG050, AXG065,

AXG080, AXG100,

AXG125

15 to 125 mm

(0.5 to 5 in.)

Clamp, Union,

Butt Weld Joint

PFA Lining

Table E

Table F

AXG002, AXG005,

AXG010, AXG015,

AXG025, AXG040, 

AXG050, AXG080,

AXG100, AXG150, 

AXG200

2.5 to 200 mm

(0.1 to 8 in.)

Wafer

Ceramics Tube

Table G

Table H

*1: 

When process connection code EA4 is specified, temperature table is changed to table in [ ].

 

The process connection code EA4 is available for AXG025, AXG040, AXG050, AXG080, and AXG100.

Summary of Contents for ADMAG TI Series

Page 1: ...ADMAG TI Series AXG Magnetic Flowmeter FM USA Explosion Protection Type IM 01E21A03 01EN 1st Edition IM 01E21A03 01EN User s Manual ...

Page 2: ... Edition 1st Edition Oct 2019 KP All right Reserved Copyright 2019 Yokogawa Electric Corporation Contents 1 Introduction 1 2 Explosion Protection Type 3 2 1 Technical Data 3 2 2 Cable Entry 7 2 3 Installation 7 2 4 Operation 12 2 5 Maintenance and Repair 12 2 6 Specific Condition of Use 12 Revision Information ...

Page 3: ...N A CAUTION sign denotes a hazard It calls attention to procedure practice condition or the like which if not correctly performed or adhered to could result in damage to or destruction of part or the entire product IMPORTANT An IMPORTANT sign denotes that attention is required to avoid damage to the product or system failure NOTE A NOTE sign denotes information necessary for essential understandin...

Page 4: ...neers responsible for installation and wiring of the instrument To ensure correct use read this manual and the applicable user s manuals as listed in IM 01E21A21 01Z1 Read Me First thoroughly before starting operation Read the general specifications as listed in IM 01E21A21 01Z1 Read Me First for its specification Trademark All the brands or names of Yokogawa Electric s products used in this manua...

Page 5: ... after tightening the cover 2 1 Technical Data Applicable Standard FM 3600 FM3610 FM3615 FM3616 FM3810 ANSI UL UL 50E NEMA 250 ANSI UL 60079 0 ANSI UL 60079 7 ANSI UL 60079 11 ANSI UL 60079 18 ANSI UL 61010 1 ANSI UL 61010 2 30 Certificate FM 17US0140X Integral Flowmeter Explosionproof Explosion Protection Code FF2 Type of Protection CL I II III GPABCDEFG IS CL I GPABCD T6 T3 Enclosure Type 4X Amb...

Page 6: ...Ambient Temperature 40 C to 60 C Temperature class T6 Power Supply 100 to 240 Va c 50 60 Hz 100 to 120 Vd c 24 Va c 50 60 Hz 24 Vd c Control Drawing DIE016 A92 Table 2 1 Temperature Ratings Model Size Process Connection Lining Temperature Table Integral Flowmeter Remote Sensor AXG002 AXG005 AXG010 AXG015 2 5 to 15 mm 0 1 to 0 5 in Wafer Flange PFA Lining Table A Table C AXG025 AXG032 AXG040 AXG050...

Page 7: ... C T3 T150 C 40 C to 150 C D 40 C to 45 C T6 T75 C 40 C to 50 C 40 C to 60 C T5 T90 C 40 C to 75 C T4 T120 C 40 C to 120 C T3 T150 C 40 C to 150 C E 10 C to 45 C T6 T75 C 10 C to 50 C 10 C to 60 C T5 T90 C 10 C to 75 C T4 T120 C 10 C to 120 C T3 T130 C 10 C to 130 C F 10 C to 45 C T6 T75 C 10 C to 50 C 10 C to 60 C T5 T90 C 10 C to 75 C T4 T120 C 10 C to 120 C T3 T150 C 10 C to 150 C G 10 C to 60 ...

Page 8: ... to 8 in flange type wafer type 250 to 300 mm 10 to 12 in flange type 350 to 400 mm 14 to 16 in flange type F0202 ai 1 1 For wafer types of 150 to 200 mm 6 to 8 in or carbon steel flange types process connection code C of 50 to 400 mm 2 to 16 in the minimum temperature is 10 C 14 F PFA Lining Remote Sensor and Integral Flowmeter high pressure type ASME Class 600 flange F0203 ai Pressure MPa psi Te...

Page 9: ...ring shall be in conduit as follows SEALALL CONDUITS WITHIN 18 INCHES In order to prevent the grounding conductor from loosening the conductor must be secured to the terminal tightening the screw with appropriate torque Care must be taken not to twist the conductor Warning In cases where the ambient temperature exceeds 50 C use external heat resistant wiring with a maximum allowable temperature of...

Page 10: ...IM 01E21A03 01EN 8 2 Explosion Protection Type 8 Read the Control Drawing All wiring shall comply with local installation requirements Integral Type Flowmeter Explosion Protection Code FJ2 F0213 ai ...

Page 11: ...IM 01E21A03 01EN 9 2 Explosion Protection Type 9 Remote Type Flowmeter Explosion Protection Code FJ2 F0214 ai ...

Page 12: ...IM 01E21A03 01EN 10 2 Explosion Protection Type 10 Integral Type Flowmeter Explosion Protection Code FT2 F0215 ai ...

Page 13: ...IM 01E21A03 01EN 11 2 Explosion Protection Type 11 Remote Type Flowmeter Explosion Protection Code FT2 F0216 ai ...

Page 14: ...orporation can repair the equipment 2 6 Specific Condition of Use In the case the electrodes and or grounding rings are made of titanium the sensor should be kept away from impacts and frictions in hazardous locations Electrostatic charges on the non metallic parts excluding glass parts or coated parts of the product shall be avoided The applicable temperature class ambient temperature range and p...

Page 15: ... 01E21A03 01EN 13 Revision Information Title ADMAG TI Series AXG Magnetic Flowmeter FM USA Explosion Protection Type Manual No IM 01E21A03 01EN Edition Date Page Revised Item 1st Oct 2019 New Publication ...

Reviews: