Model 320310 12 kV DC High Tension Probe (Order Discontinued Item)
Rating Voltage:
DC 12 kV
Accuracy:
±5% of rating (when connected to the tester 320110)
Current Loss:
approximately 20 μA
Allowable Input Voltage:
DC 15 kV
Model 320410 12A DC Shunt (Order Discontinued Item)
Rating Current:
DC 12 A
Rated Voltage Drop:
220 mV
Accuracy:
±3% of rating (when connected to the tester 320110)
Model 320510 Clip-On Current Transformer (Order Discontinued Item)
Rating Current:
AC 12/30/60/120/300 A AC
Accuracy:
±3% of rating (when connected to the tester 320110)
Frequency Characteristics: less than ±1% of indication value at 50 and 60 Hz