Momentary (or relay) mode
This mode can be used to control a
dimmer or ringer
by means of the free contact of the MTR2000ER.
In momentary mode, the contact of the MTR2000ER follows the transmitter pushbutton activation: the
MTR2000ER contact is closed if the transmitter pushbutton is pressed. The contact will be open if the
pushbutton is released.
1. Make
10
short presses on any pushbutton of the transmitter (Configuration Menu). The transmitter LED
will flash rapidly.
2. While the LED is flashing, make
17
short presses of the pushbutton on the transmitter to be configured.
3. At the end of the
17
short press sequence, the LED will flash 7 times to confirm the configuration.
Pulse mode
This mode may be used to
control a gate, a garage door or to open a door with electric lock
.
In pulse mode, the MTR2000ER contact generates a single pulse of 0.5 seconds whenever the transmitter
pushbutton is pressed.
1. Make
10
short presses on any pushbutton of the transmitter (Configuration Menu). The transmitter LED
will flash rapidly.
2. While the LED is flashing, make
16
short presses of the pushbutton on the transmitter to be configured in
pulse mode.
3. At the end of the
16
short press sequence, the LED will flash 6 times to confirm the configuration.
Flashing mode
In this mode, one or more lights will flash to alert
hearing impaired users
instead of an auditory signal. An
E2BP transmitter connected to the ringer pushbutton must be added.
Making
22
short presses will activate or deactivate flashing mode. Additionally, make 10 short presses on any
pushbutton on the transmitter (Configuration Menu). The transmitter LED will flash rapidly. Then make 19
short presses on the desired pushbutton.
ADDITIONAL FUNCTIONS
DS1054-012F
P10
Two radio centralisation modes are possible, depending on the number of modules to be controlled and the
distance between the various modules:
• Direct mode: up to 4 modules per pushbutton
• Radio bus mode: unlimited number of modules
Refer to the transmitter instruction booklet or the “Radio Memo” or go to www.yokis.com for more information.
CENTRALISATION
IMPORTANT
Modules may also be centralised using a driver wire. It may be useful to plan the use a dedicated
driver wire for centralisation in some peculiar installations, during module wiring.
WARRANTY
: In addition to the warranty required by law, this product is
guaranteed for 5 years
from date of manufacture. The material must
be used according to the instructions provided and for its intended use. Faults must not be caused by deterioration or accidents resulting from
negligence, anomalous use or incorrect installation. In all cases, the warranty only includes replacement of faulty products. No compensation for
loss or damage may be claimed.
Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C
For technical information, go to www.yokis.com or call:
Customer Service: +39 011.23.39.810 - export dept. Phone: +39 011.24.00.250/256 -
Fax: +39 011.24.00.296