Press the pushbutton to be connected on the
transmitter (E) 5 times**.
The transmitter LED will start flashing for 30
seconds, indicating that the system is waiting
for connection.
** Each press must last less than 0.7 seconds
Briefly press the pushbutton in the ‘connect’ hole
of the receiver (R)
(on the front or the back of the
receiver)
with the point of a pencil while the
transmitter LED is flashing.
The transmitter LED will stop flashing.
Warning: the receiver must be powered.
D I R E C T M O D E
technical specifications:
- CR2032 Lithium battery (included)
- Battery life > 7 years
- Max. 4 receivers per transmitter button
- Operating temperature: from -10 to + 50°C
- IP54 protection
- Max. relative humidity 80%
- Frequency: 2,4 GHz
- Transmission: two-way
RADIO TRANSMITTERS
1
2
Simply repeat the same procedure
to delete a connection
Switches can be used instead of pushbuttons to drive Mtr2000er
receivers
. In this case, switch 5 times rapidly (not 10!) instead of using the 5
press sequence. Repeat the connection procedure by pressing 5 times to use a
pushbutton again instead of the switch.
the Led will light up on transmitters
only if radio transmission was successful
The E2BP/E2BPP/E4BPP may be wired behind pushbuttons (or switches) of any
model. Wiring both channels is not indispensable: a single pushbutton can be
used connected to a single channel.
all YoKiS transmitters are compatible with
YoKiS receivers
(relays, dimmer and Shutter Modules).
radio raNGe:
Standard range:
• In the same room (< 100 m²)
• 50m in open range
(Range may be reduced by presence of metallic
elements, crossing of walls or partitions)
Power range:
• Inside 100m² apartments with perpendicular
crossing of main wall or ceiling
• 250m in open range
(Range may be reduced by presence of metallic
elements, crossing of walls or partitions)
radio traNSMiSSioN:
the transmitter Led lights up only if radio
transmission was successful.
Adding an intermediate receiver will allow to solve a
problem of insufficient range (see § “How to increase
the range”).
DS1054-009F
e2BP
5454402
2-channel flush-mounted transmitter
tLC2C
5454401
2-pushbutton remote control
tLM1t45
5454411
1-pushbutton wall-mounted remote control
tLM2t45
5454406
2-pushbutton wall-mounted remote control
tLM4t45
5454412
4-pushbutton wall-mounted remote control
POWER RANGE
E2BPP
5454413
2-channel flush-mounted POWER transmitter
E2BPPX
5454414
2-channel flush-mounted POWER transmitter
POWER with external aerial
E4BPP
5454427
4-channel flush-mounted POWER transmitter
E4BPPX
5454428
4-channel flush-mounted POWER transmitter with
external aerial
TLC4CP
5454425
4-pushbutton POWER remote control
TLC8CP
5454423
8-pushbutton POWER remote control
GALET8TP
5454424
8 pushbutton flat POWER remote control
TLM1T45P
5454417
1-pushbutton wall-mounted POWER remote
control
TLM2T45P
5454419
2-pushbutton wall-mounted POWER remote
control
TLM4T45P
5454421
4-pushbutton wall-mounted POWER remote
control
P8
A command can be centralised by repeating the same procedure on up to four receivers. In case that more
than 4 receivers should be driven, use the Radio Bus.
GB
DIRECT MODE CENTRALISATION
GB ES
WARNING: Explosion risk if the battery is replaced with a battery other
than the referred one. Dispose of the used batteries as per local stan-
dards.
E2BP/E2BPP E4BPP