background image

3-4. Discrete adjustment features

- Brightness levels switches upward with holding the button. When the maximum or the 

minimum brightness level is reached, the direction changes (after a small pause).
- The “click-and-hold” command can be also used for changing the direction of the 

adjustment.
- There are five brightness levels (Min-Low-Med-High-Max), which switches with 0.7 sec. 

interval.

3-5. Features of the maximum mode with fast access

- Short click returns to the previous mode (and turns the flashlight OFF if it was OFF before 

using Max).
- Hold starts adjusting the brightness down with switching to basic brightness modes.
- Click-and-hold turns OFF the flashlight (always, regardless of the previous mode).
- If Max is activated by a command with holding the button (“hold” for example), 

the flashlight will automatically decrease the brightness with continue holding the 

button. This function can be used for scrolling the modes “from highest”.
 

3-6. Slots features

When using “2 clicks” and “2 hold” commands, the light does not turn off during 

the execution of a command. This is done for ease of use maximum or additional mode 

on these slots, without flashes when activated.
When using commands with 3 or more clicks, the light turns off before the execution of a 

command.

Summary of Contents for Unicorn 1.0

Page 1: ...ion with particular command slot bringing to the main menu particular options of user interface changing smooth or discrete adjustment memory of modes on off button backlight in the off and on state c...

Page 2: ...you configure 4 select the option number to be executed by this command with clicking the button corresponding numbers of times Next you can set up other commands in the same way exit the slot setting...

Page 3: ...g the button enable slot setting mode 7 clicks hold the button will flash green execute the 4 clicks command the button will blink green press the button 6 times the number of the battery check option...

Page 4: ...ion as UI 1 enter the engineering menu screw the cap until tight while holding the button execute the command set current configuration as UI 1 13 clicks hold the button will flash green after 1 2 sec...

Page 5: ...50 C Please note that the thermal control is working in the process of the setting so you can not heat the lamp substantially above 50 degrees The set temperature will be used in all UIs but it will b...

Page 6: ...ness of the mode from which they were turned on or 170 lm if turned on from the OFF state When the memory of modes is off the current memorized at the moment brightness mode will be set as the start m...

Page 7: ...Hold starts adjusting the brightness down with switching to basic brightness modes Click and hold turns OFF the flashlight always regardless of the previous mode If Max is activated by a command with...

Reviews: