background image

2. THERMAL CONTROL SETTINGS

Unicorn is equipped with active thermal control system that changes brightness 

depending on the degree of heating of the flashlight. The flashlight is already set up for 

comfortable work, temperature threshold is 50

°C

; sensor is calibrated at room 

temperature of 25

°C

.

If necessary, you can reconfigure the thermal control limit on your own, or reset the 

settings and recalibrate the temperature sensor.

2-1. Manual thermal control setting

Allows setting a comfortable degree of flashlight heating:
1) Enter the engineering menu (screw the cap until tight while holding the button);
2) Turn on the flashlight on Maximum and wait for the desired temperature;
3) Execute a “9 hold” command, current temperature of the flashlight will be set 

as an operating threshold of a thermal control.
4) After 1-2 seconds exit the engineering menu.
The default threshold for thermal control is 50

°C

Please note that the thermal control is working in 

the process of the setting, so you can not heat the lamp substantially above 50 degrees.

The set temperature will be used in all UIs, but it will be reset to default when the flashlight 

is reset (12 clicks) or when the temperature sensor is calibrated.

2-2. Temperature sensor calibration

This function allows resetting temperature control and re-calibrating temperature sensor 

of the flashlight. During calibration, current air temperature will be recorded as 25

°C

, the 

temperature sensor will proceed from this value during temperature measurements.
Adjustment must be made at a room temperature (~ 25

°C

); the flashlight should not be 

heated by working before the adjusting.
1) Enter the engineering menu;
2) Execute the command “20hold”, the button will flash green. 
3) After 1-2 seconds exit the engineering menu.
The results of the temperature sensor calibration will stay even after resetting of the 

flashlight. Also, when calibrating the temperature sensor, the results of manual 

adjustment of the temperature control will be automatically reset (p.2-1).

Summary of Contents for Unicorn 1.0

Page 1: ...ion with particular command slot bringing to the main menu particular options of user interface changing smooth or discrete adjustment memory of modes on off button backlight in the off and on state c...

Page 2: ...you configure 4 select the option number to be executed by this command with clicking the button corresponding numbers of times Next you can set up other commands in the same way exit the slot setting...

Page 3: ...g the button enable slot setting mode 7 clicks hold the button will flash green execute the 4 clicks command the button will blink green press the button 6 times the number of the battery check option...

Page 4: ...ion as UI 1 enter the engineering menu screw the cap until tight while holding the button execute the command set current configuration as UI 1 13 clicks hold the button will flash green after 1 2 sec...

Page 5: ...50 C Please note that the thermal control is working in the process of the setting so you can not heat the lamp substantially above 50 degrees The set temperature will be used in all UIs but it will b...

Page 6: ...ness of the mode from which they were turned on or 170 lm if turned on from the OFF state When the memory of modes is off the current memorized at the moment brightness mode will be set as the start m...

Page 7: ...Hold starts adjusting the brightness down with switching to basic brightness modes Click and hold turns OFF the flashlight always regardless of the previous mode If Max is activated by a command with...

Reviews: