The CM90-BUV can be used to effectively cool the following places: packaging & food processing 
industries, manufacturing factories, warehouses, hospitals, clinics, schools, waiting rooms, cafes, 
shopping malls, supermarkets, laundry rooms, offices, homes, commercial kitchens, markets, large 
entertainment centres, underground parking garages, stations, events, carnivals, farms.

You can also use our CM90-BUV in existing air-conditioned venues if additional cooling is required. 
The typical process of air conditioning will result in drier air, thus allowing faster evaporation process 
to take place for our cooler. Therefore, using the CM90-BUV in these areas will have enhanced overall 
cooling effects.

where Can oUr CoolerS Be USed?

Model Number: CM90-BUV
Air Flow: 9000m

3

/hr

Rated Power: 350 Watt
Rated Current: 1.6 Amp
Voltage & Frequency: 220V / 50Hz
Gross Weight: 44KG
Packing Dimension: 86cm x 57cm x 132cm
Product Dimension: 78cm x 52cm x 134cm
Noise: 60dB
Water Storage: 100L
Fan Type: Axial Fan
Cooling Method: Evaporative

Environment Relative Humidity: <95%
Atmospheric Pressure: 86kpa – 106kpa
Water Supply Pressure: 0.15mpa – 0.6mpa
Voltage Deviation: + 10% 
No Corrosive Gases Present

SPeCIfICatIonS at one glanCe

BeSt workIng enVIronMent

Summary of Contents for Cooling Monsters CM90-BUV

Page 1: ...Evaporative Cooling CM90 BUV...

Page 2: ...of evaporative coolers utilize high speed blades that generate large air volume along with the introduction of UV disinfection within the water tank Through both natural and scientific processes it u...

Page 3: ...irectional inlet cooling evaporative media Mounted on castors for greater mobility 3 adjustable wind speeds Low electrical consumption Environmentally friendly Digital LED display control panel 24 Hou...

Page 4: ...skin or eyes It also greatly improves microbial air output quality and ensures that you are breathing cleaner air 3 new features on our CM90 BUV cooler Black is an inherently beautiful colour It gives...

Page 5: ...elimination In this cooler the key function of the UV light is to continuously cleanse the water before the evaporation process takes place The disinfecting properties of the UV lamp also greatly redu...

Page 6: ...the cooler and blow out to the front This process draws hot air from the atmosphere into the cooler passing through the moistened evaporative media and disperse back to the atmosphere Through this ai...

Page 7: ...nk via the water input slot located behind the product 6 Avoid splashing water onto the motor to prevent damaging the electrical components in the unit 7 To prevent overflowing always fill the water B...

Page 8: ...at rest and the cooler will only operate as a normal fan for air circulation UV light will turn off SPEED Press this button to set the fan to desired speeds P1 is low speed P2 is medium speed P3 is hi...

Page 9: ...WEAKENED COOLING EFFECT If you experience weakened cooling effect there is a chance that the water and or filter is dirty Simply conduct regular cleaning If problem persists you can contact your Cooli...

Page 10: ...ent of which the product is regularly deployed Do s Do not attempt to operate the cooler if it is faulty or its cord s and or plug appears to be damaged in any way Also avoid contact with parts that h...

Page 11: ...ll result in drier air thus allowing faster evaporation process to take place for our cooler Therefore using the CM90 BUV in these areas will have enhanced overall cooling effects Where can our cooler...