background image

WWW.YES-RC.COM

8

Waste Time

The battery becomes warm after cycles of charge/discharge process. 
The program will insert a time delay after each charge/discharge 
process to allow the battery enough time to cool down before 
beginning next cycle of charge/discharge process. The valid value 
ranges from 1 to 60 minutes. When the charge process starts, the 
integrated safety timer starts to run simultaneously. If error detected 

or the termination circuit can not detect whether the battery is fully charged or not, this unit is 
programmed to prevent overcharging. Please refer to the below statement to calculate the timer 
you set.

Capacity Cut-Off

The program provides maximum capacity protection function. If the 
Delta peak voltage can not be detected or the safety timer times out, 
the charge process will stop automatically, when the battery reaches 
the user-set maximum charge capacity. 

Key Beep / Buzzer

The beep to confi rm users’ operation sounds every time a button 
is pressed. The beep or melody sounds at various times during 
operation to confi rm different mode change. These functions can be 
switched on or off. 

Input Power

This function monitors the voltage of the input battery used to power 
this charger. If the voltage is lower than user-set value, the program 
will end forcibly to protect the input battery.

Safe timer Calculation

When charging NiCd or NiMH batteries, divide the capacity by cur-
rent, then divide the result by 11.9, set this number of minutes as 
the value for safety timer setting. If the charger stopped at this time 
threshold, about 140% of the capacity will have been fed into the 
battery.

For example:

Capacity  

Current  

Safety Time

2000mAh  

2.0A  

(2000/2.0=1000)/11.9=84 minutes

3300mAh  

3.0A  

(3300/3.0=1100)/11.9=92 minutes

1000mAh  

1.2A  

(1000/1.2=833)/11.9=70 minutes

User settings and menu’s

As default this charger will be set to typical user settings when it is connected to a 12V battery 
for the fi rst time. The screen displays the following information in sequence and the user can 
change the parameter on each screen.

If you need to alter the parameter value in the program, press Start/Enter key to make it blink then 
change the value with ”INC”or”DEC” key. The value will be stored by pressing Start/Enter key 

Waste time
CHG/DCHG 5 min

-

     

+

<”DEC”    “INC”> 

Capacity Cut-off
ON  

5000mAh

-

     

+

<”DEC”    “INC”> 

Key Beep    ON
Buzzer 

   ON

-

     

+

<”DEC”    “INC”> 

Input power low 
Cut-Off   10.0V

-

     

+

<”DEC”    “INC”> 

Safety timer
ON 120 

min

-

     

+

<”DEC”    “INC”> 

Summary of Contents for I-Peak 665

Page 1: ...Ref Y 023 I Peak 665 Professional Intelligent Digital Balance charger Instruction Manual...

Page 2: ...f this product or for any loss or damage arising from omissions or inaccuracies in the associated instructions or materials included with this product We reserve the right to modify the design of this...

Page 3: ...nt 1C 2C depends on the performance of cell Discharge voltage cut off level 0 85V cell NiCd 1 0V cell NiMH Li ion Voltage level 3 6V cell Max charge voltage 4 1V cell Allowable fast charge current 1C...

Page 4: ...t the circuit automatically and alarm once detecting any malfunction All the programs of this product were controlled through two way linkage and communication to achieve the maximum safety and minimi...

Page 5: ...e keeps being monitored If it drops below the lower limit the process will be ended automatically Data store load The maximum five batteries data can be stored for users convenience You can keep the d...

Page 6: ...om mended charging current and charging time Especially the Lithium battery should be charged according the charging instruction provided by the manufacturer strictly Attention should be paid to the c...

Page 7: ...cell count incorrectly at the beginning of charge or discharge process Otherwise default value is recommended to use Delta Peak Sensitivity The NIMH Sensitivity D Peak shows the trigger voltage for au...

Page 8: ...d on or off Input Power This function monitors the voltage of the input battery used to power this charger If the voltage is lower than user set value the program will end forcibly to protect the inpu...

Page 9: ...ead directly into this chargers balance ports If you are not sure what type of lead you have then check with your local model shop before connecting to the balance ports on this charger The main batte...

Page 10: ...you can start charging by press Start Enter button If not press Batt type Stop button to go back to previous screen to carefully check the number of cells of the battery pack before going ahead 4 Thi...

Page 11: ...atus during charge process Press Batt type Stop key once to stop the charge process Li3s 2 0A 12 59V BAL 022 43 00682 Number of cells Battery voltage Charging time Supplied capacity Charging current F...

Page 12: ...you can set up the current and voltage of the battery pack Charging and dis charging will make the batteries come to the voltage level of storage state LiPo STORAGE 2 0A 11 1V 3S This screen shows the...

Page 13: ...c acid battery program This program is only suitable for charging Pb lead acid battery with nominal voltage from 2 to 20V Pb lead acid battery is completely different from NiCd NiMH battery These batt...

Page 14: ...Start Enter key again to store the parameter value you set Press Batt type Stop key to end the program Pb 6 0 4A 12 59V DSC 022 43 00682 Battery type Battery voltage Elapsed time Discharged capacity...

Page 15: ...t the program NIMH DISCHARGE 1 0A 11 5V The screen indicates the discharging state You can press Start Enter key to alter discharge current Press Start Enter again to store the value Press Batt type S...

Page 16: ...meter Setting of the parameter in this screen will not affect the charge and discharge process They just represent the specification of the battery The following screens will automatically be displaye...

Page 17: ...tor voltage of each cell while the battery is connected with each port of the charger End Voltage 12 06V 3s The final voltage when the program ended Capacity Cut Off ON 5000mAh Safety Timer ON 200min...

Page 18: ...d CYCLE DCHG CHG 5 Start Dec Inc NiCd CYCLE DCHG CHG 3 2sec Start DCHG 1 0005mAh CHG 1 0000mAh Batt Dec Type PROGRAM SELECT LiPo BATT LiPo CHARGE 5 0A 22 2V 6S Start Dec Inc Start LiPo BALANCE 5 0A 22...

Page 19: ...b 4 1 3A 9 80V DSC 000 31 00004 Pb CHARGE 0 6A 8 0V 4P Start Dec Inc Pb CHARGE 0 6A 6 0V 3P Batt Dec Type PROGRAM SELECT SAVE DATA Start SAVE 05 NiCH 7 4A 5000mAh Start 2sec Start 2sec Start Dec Inc S...

Page 20: ...Wrong connection of the connector detected please check the connec tor and cable The charger has malfunctioned for some reason Seek professional advice The processor detects that the battery has dropp...

Reviews: