IMPORTANT NOTE 

 

 
READ  AND  UNDERSTAND  THIS  MANUAL    PRIOR  TO  USING  THIS                  
INSTRUMENT.  CAREFULLY  READ  THE  WARRANTY  POLICY,  SERVICE       
POLICY,  NOTICES,  DISCLAIMERS  AND  REVISIONS  ON  THE  FOLLOWING 
PAGES. 
 
THIS  INSTRUMENT  SHOULD  BE  INSPECTED  AND  CALIBRATED  REGULARLY 
BY A QUALIFIED AND TRAINED  TECHNICIAN. 
 
THIS  INSTRUMENT  HAS  NOT  BEEN  DESIGNED  TO  BE  INTRINSICALLY  SAFE. 
FOR  YOUR  SAFETY, 

DO  NOT 

USE  IT  IN  CLASSIFIED  HAZARDOUS  AREAS 

(EXPLOSION-RATED ENVIRONMENTS). 

 

INSTRUMENT SERIAL NUMBER: 

____________________________________________________________________ 
 

PURCHASE DATE: 

____________________________________________________________________ 
 

PURCHASED FROM: 

____________________________________________________________________ 

 

WARRANTY POLICY 

 

CRITICAL  ENVIRONMENT  TECHNOLOGIES  CANADA  INC.  (FORMERLY  YES 
ENVIRONMENT TECHNOLOGIES INC.) WARRANTS THIS INSTRUMENT TO BE 
FREE  FROM  DEFECTS  IN  MATERIALS  AND  WORKMANSHIP  FOR  A  PERIOD 
OF  EIGHTEEN  MONTHS,  INCLUDING  CO2  SENSOR,  FROM  THE  DATE  OF  
PURCHASE BY THE ORIGINAL OWNER. IF THE PRODUCT SHOULD   BECOME 
DEFECTIVE  WITHIN  THIS  WARRANTY  PERIOD,  WE  WILL  REPAIR  OR          
REPLACE, IT AT OUR DISCRETION.  
 
THE WARRANTY STATUS MAY BE AFFECTED IF THE INSTRUMENT HAS NOT 
BEEN USED AND MAINTAINED AS PER THE INSTRUCTIONS IN THIS MANUAL 
OR  HAS  BEEN  ABUSED,  DAMAGED  OR    MODIFIED  IN  ANY  WAY.  THIS          
INSTRUMENT  IS  ONLY  TO  BE  USED  FOR  PURPOSES  STATED  HEREIN.  THE 
MANUFACTURER IS NOT LIABLE FOR  AUXILIARY  INTERFACED EQUIPMENT 
OR  CONSEQUENTIAL DAMAGE. 
 
DUE  TO  ONGOING  RESEARCH,  DEVELOPMENT  AND  PRODUCT  TESTING, 
THE MANUFACTURER RESERVES THE RIGHT TO CHANGE SPECIFICATIONS 
WITHOUT  NOTICE.  THE  INFORMATION  CONTAINED  HEREIN  IS  BASED  ON 
DATA  CONSIDERED  ACCURATE.  HOWEVER,  NO WARRANTY  IS  EXPRESSED 
OR IMPLIED REGARDING THE ACCURACY OF THIS DATA. 
 
ALL  GOODS  MUST  BE  SHIPPED  TO  THE  MANUFACTURER  BY  PREPAID 
FREIGHT.  ALL  RETURNED  GOODS  MUST  BE  PRE-AUTHORIZED  BY             
OBTAINING  A  RETURN  MERCHANDISE  AUTHORIZATION  (RMA)  NUMBER. 
CONTACT  THE  MANUFACTURER  FOR  A  NUMBER  AND  PROCEDURES        
REQUIRED FOR PRODUCT TRANSPORT.  

Summary of Contents for Falcon-II

Page 1: ...ay Delta BC V4G 1M3 Canada Phone 604 940 7007 Fax 604 940 7044 www yestek com REV A JUNE 2 2008 Falcon II Next Generation Air Quality Monitor CO2 Temperature OPERATION MANUAL Critical Environment Tech...

Page 2: ...2...

Page 3: ...IP FOR A PERIOD OF EIGHTEEN MONTHS INCLUDING CO2 SENSOR FROM THE DATE OF PURCHASE BY THE ORIGINAL OWNER IF THE PRODUCT SHOULD BECOME DEFECTIVE WITHIN THIS WARRANTY PERIOD WE WILL REPAIR OR REPLACE IT...

Page 4: ...LIABILITY REASONS CETCI HAS A POLICY OF PERFORMING ALL NEEDED REPAIRS TO RESTORE THE INSTRUMENT TO FULL OPERATING CONDITION PRIOR TO SHIPPING EQUIPMENT TO CETCI CONTACT OUR OFFICE FOR AN RMA RETURNED...

Page 5: ...S MANUAL ALL INFORMATION CONTAINED IN THIS MANUAL IS BELIEVED TO BE TRUE AND ACCURATE AT THE TIME OF PRINTING HOWEVER AS PART OF IT S CONTINUING EFFORTS TO IMPROVE IT S PRODUCTS AND THEIR DOCUMENTATIO...

Page 6: ...E 7 1 0 GENERAL 8 2 0 SPECIFICATIONS 8 9 3 0 DIMENSIONS 10 4 0 INSTRUMENT FEATURES 11 12 5 0 OPERATION 13 5 1 OPERATING MODES 13 5 2 DETAILED OPERATING INSTRUCTIONS 13 16 5 22 OPERATION MODE ADJUSTMEN...

Page 7: ...mory The instrument may be hand held or will easily stand on a flat surface The FALCON II instruments are manufactured to provide good value to the end user Calibration and repair is available at our...

Page 8: ...wall configuration only Power Requirement 160 mA Peak 15 mA average from 6V Outputs Normally Low 100mA max 24 VDC Adjustable set point factory setting is 1000ppm hysteresis is 50ppm One RJ 45 Connecto...

Page 9: ...er C or 2 ppm per C whichever is greater referenced to 25 C Pressure Dependence 0 13 of reading per mm Hg Corrected via user input for altitude Response Time 2min for 63 of step change Warm Up Time 60...

Page 10: ...10 3 0 DIMENSIONS 6 50 165mm 3 19 81 1mm 0 96 24 3mm...

Page 11: ...INSTRUMENT FEATURES FUNCTION PUSH BUTTONS MODE UP DOWN ENTER left to right ON OFF PUSH BUTTON LED INDICATOR LCD DISPLAY TEST GAS INLET OPENING FLIP DOWN STAND ALKALINE BATTERY ACCESS DOOR WALL ADAPTER...

Page 12: ...12 4 0 INSTRUMENT FEATURES CONT D Changing Alkaline Batteries...

Page 13: ...d ALARM Alarm when CO2 concen tration exceeds one threshold alarm Alarm level can be changed through the keypad menu The audible alarm can be switched on off through the keypad menu when the speaker i...

Page 14: ...go through the following sequence Temp C Temp F Vent Rate lps Vent Rate cfm p NOTE lps refers to Liter Per Second Per Person cfm p refers to Cubic Feet Per Minute Per Person 5 22 OPERATION MODE ADJUST...

Page 15: ...e Mode button until OUTSIDE flashes 3 2 Press Enter to show OUTSIDE CO2 and PPM flashes Press Up Down to adjust the reading 3 3 Press the Enter save the setting and return to the User Mode After modif...

Page 16: ...adings since the instrument was last switched on 6 1 Press the Mode button until MAX MIN flashes 6 2 Press Enter button MAX and MIN CO2 reading shows alternating 6 3 CLR will flash if press Up Down Pr...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Reviews: