YR-1190
-10-
Attention
In address state, when connect multiple models, do not connect to controller, it
will run as master and slave. Operate one of the model, this model will auto act as
master, other models run the same as master. When connect to controller, all
models will be controlled by controller.
When a team of machines is connected to controller
,
for the last machine, one
DMX signal output or input is vacant. This vacant output or input should be
connected a terminal organ. Find a DMX output or input connector, inside the
connector, weld a120ohm, 1/4 w resistance between pin2 and pin3, then inset this
connector to the vacant output or input.
Master and slave mode
Master and slave: select one machine as master,
set it in menu state. Other
machine set to be DMX state as slaves, Connect all models by signal cable. Then,
For YR-1190
,
power connection can not be more than 8pcs. If more
than 8pcs, please connect to another power input.