background image

12

WARRANTY INFORMATION

Ritchie Engineering guarantees YELLOW 

JACKET

®

 products to be free of defective 

material and workmanship which could 

affect the life of the product when used 

for the purpose for which it was designed.  

This warranty does not cover items that 

have been altered, abused (including 

failure to use the correct type of vacuum 

pump oil) or returned solely in need of field 

service maintenance.

If found defective, we will either replace 

or repair at our option products within 

warranty period. Returns must be prepaid.
Warranty does not cover use of lithium 

bromide, ammonia or leak stop type 

products.

How to Obtain Service

Most returned pumps are merely in need of 

normal field service maintenance, such as 

changing oil or making minor adjustments.  

In many instances, the troubleshooting 

information in this manual can save you 

the time and effort of returning your 

pump.  When the information contained in 

this manual, however, does not solve the 

problem, please call for service.

©

2020 Ritchie Engineering Company, Inc.

Printed in the USA

           PN #143060_RevB

Warranty is void if the set vacuum pump voltage does not match the power supply.

Summary of Contents for 93714

Page 1: ...I Vacuum Pump Operation and Maintenance Manual Models 9371x 9374x 9376x 9378x 9379x PN 143060_RevB 5 Commonwealth Ave Woburn MA 01801 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEq...

Page 2: ...arrange inspection of the pump and packaging The CARRIER ALONE is responsible for handling and settling your claim Ritchie Engineering will cooperate in assessing damage if the pump is returned to the...

Page 3: ...motor can run on voltage as low as 85 volts with no issue and draws fewer amps than AC motors Large Impact Resistant Toughened Nylon Feet Reduces vibration and increases durability and longevity Help...

Page 4: ...d stage similar to two single stage pumps connected together If air a non condensable remains in the system it collects on the high side reduc ing system efficiency This causes a rise in head pressure...

Page 5: ...uum just prior to shut off 7 Disconnect pump and put cap on intake to keep out contaminants 8 If an extension cord is needed refer to the below chart for proper sizing 6 Use the 4 in 1 Vacuum Charge V...

Page 6: ...3 Replace cover and screw down by hand Do not use drill as cover could crack CAUTION Always remove cord before changing voltage Incorrect voltage setting can result in destruction of controller elect...

Page 7: ...mosphere and switch on pump run up to speed before connecting to system Four Most Common Comments on Pump Return Paperwork Your SuperEvac PLUS II pump features a heavy duty high torque motor for cold...

Page 8: ...dropped Micron gauge malfunction Poor motor performance Dirty oil Air leaks System leaks Fitting sealant compound Call factory Verify with second gauge Repair or replace Flush 1 to 3 times Repair or...

Page 9: ...coupling Replace motor Tighten bolts Adjust replace coupling Pump Cartridge Dirt low improper oil Air leaks 1 Caps connections 2 Gaskets O rings 3 Fittings 4 System leak Flush and replace oil Tighten...

Page 10: ...92741 92741 3 Oil fill cap and seal 93390 93390 93390 93390 4 Oil fill fitting 93391 93391 93391 93391 5 Pair of sight glass screws 92933 92933 92933 92933 6 Sight glass bezel 92934 92934 92934 92934...

Page 11: ...93366 93366 22 Complete parts for blank off 93367 93367 93367 93367 Motor 23 SuperEvac Universal Motor 93713 93713 93713 93713 24 Locking IEC to NEMA 5 15 92755 92755 92755 92755 25 Locking IEC to UK...

Page 12: ...tion products within warranty period Returns must be prepaid Warranty does not cover use of lithium bromide ammonia or leak stop type products How to Obtain Service Most returned pumps are merely in n...

Reviews: