13
O
P
E
R
A
T
I
N
G
M
A
N
U
A
L
GB
at least 1,38 MPa.
If the product features the ability to change the direction of air outlet, direct it away from the human body. Prolonged exposure
to a stream of compressed air can lead to a cooling of place reached by the stream of compressed air, which can cause serious
injuries.
Check the correctness of connection and operation by applying the tool outlet to a piece of wood or wood-based material and by
pressing the trigger once or twice.
Filling the magazine (V)
Note! The magazine should be fi lled only when the product is disconnected from the compressed air supply.
Only fasteners listed in the user manual may be used.
When fi lling, hold the tool in such a way that the outlet is not directed towards the user or towards others.
When fi lling, do not hold your fi nger on the trigger.
Pull back the latch of cover of fastener feeding mechanism and open the cover. Then open the magazine cover.
The magazine features a raised fl oor that facilitates the transport of shorter fasteners. In order to change the position of magazine
fl oor, raise the magazine’s axle and turn it clockwise so that the axle’s spline under the magazine fl oor hooks against the notch
in the inner magazine’s axle (VII). Make sure that the magazine fl oor has been locked in its position and that it is not possible to
change the position. Possible positions of the magazine fl oor are marked on the magazine’s wall.
Put the fastener belt onto the magazine’s axle, some of the fasteners intended for nailing should be directed towards the magazine
fl oor. Free end of the belt should be directed towards the outlet of fasteners. Splines of the feed mechanism should be placed
between the fi rst and second fasteners, and the fastener heads should stay in the guide located above the feed mechanism cover.
Close the magazine cover and then secure it by closing and securing by mans of a latch of a cover of fastener feed mechanism.
Make sure that none of covers opens by itself during the work.
Working with product
The product has a single sequential start system. This means that to start the product, you need to run both the trigger and the
lock.
In such a way that after applying the product to starting place, only a single operation is started after pulling the trigger. Subse-
quent nailing operations can only be carried out after the trigger returns from the neutral position and has been pulled again, while
the lock is kept pressed all the time.
Press the tool in the nailing area and pull the trigger (VI).
If the fastener has been nailed too deep, reduce the pressure in the system every 0.05 MPa until the desired eff ect is achieved.
If the fastener protrudes from the workpiece, increase the pressure in the system every 0.05 MPa until the desired eff ect is
achieved. Do not exceed the maximum pressure for the device.
It is recommended to apply at work the lowest possible pressure, which will save energy, reduce noise, reduce tool wear and
increase work safety.
If the fasteners are jammed, disconnect the tool from the compressed air supply. Disconnect the tool connector from the hose
quick coupler supplying the compressed air. Then open both covers as in the case of fi lling the magazine and remove the jammed
fasteners.
MAINTENANCE
Never use petrol, solvents or other infl ammable liquids to clean the tool. The fumes may ignite and cause an explosion of the tool
and serious injuries. Solvents used to clean the handle of the tool and its body may cause softening of the sealing. Dry the tool
thoroughly before the work is commenced.
In case of any irregularities in the operation of the tool, it must be immediately disconnected from the pneumatic system.
All the elements of the pneumatic system must be protected from contamination. The contamination in the pneumatic system may
damage the tool and other elements of the pneumatic system.
Maintenance of the tool before each use
Disconnect the tool from the pneumatic tool.
Before each use, it is necessary to place a small amount of maintenance liquid (e.g. WD-40) in the air inlet.
Connect the tool to the pneumatic system and set it in motion for approximately 30 seconds in order to distribute the maintenance
liquid inside the tool and clean it.
Disconnect the tool from the pneumatic tool again.
Place a small quantity of SAE 10 oil inside the tool through the air inlet and special holes. It is recommended to use SAE 10 oil
designed for maintenance of pneumatic tools. Connect the tool and set it in motion for a while.
Attention! WD-40 may not be used as the proper lubricating oil.
Summary of Contents for YT-09213
Page 22: ...22 RUS...
Page 23: ...23 RUS 10 CEN CENELEC...
Page 24: ...24 RUS SAE 10 II IV 13 8 V VII...
Page 25: ...25 RUS VI 0 05 a 0 05 a WD 40 30 SAE 10 SAE 10 WD 40 6 100...
Page 26: ...26 RUS 0 3 MPa...
Page 28: ...28 UA K...
Page 29: ...29 UA 10 CEN CENELEC...
Page 30: ...30 UA SAE 10 II IV 13 8 V VII VI 0 05 a 0 05 a...
Page 31: ...31 UA WD 40 30 SAE 10 SAE 10 WD 40 6 100 0 3 MPa...
Page 84: ...84 GR...
Page 85: ...85 GR 10 O CEN CENELEC E i...
Page 86: ...86 GR SAE 10 II IV 13 8 bar V VII VI 0 05 MPa 0 05 MPa...
Page 87: ...87 GR WD 40 30 SAE 10 SAE 10 WD 40 6 100 0 3 MPa...