4.2
TROUBLESHOOTING BY ALARM CODES (Cent’d)
4.2.13 ALARMS 3061 TO 3068 (MOTOR OVERLOAD)
Table 4.15
Cause of Trouble
I
Check Method
Cutting condition is too
severe.
Did it occur during drilling and/or
threadcutting ?
Machine runs heavily
due to shortage of
lubricant on the guide
of machine.
AC servo drive unit or
FC300B failure
Check the oil film on the guide face.
Motor overload alarm activates even if
wiring is correct.
It may cause an alarm.
S o l u t i o n
Wait until temperature
of servo motor cools down.
Then, restart operation
by alleviating the condition.
Check oil tank and oil
pipe according to instruc-
tion manual of machine.
Replace AC Servo drive
unit or FC300B board.
Contact your YASKAWA
representative.
4.2.14 ALARMS 3081 TO 3088 (PG DISCONNECTION ERROR)
Signal wire disconnection check of A and B phases from
PG.
Table 4.16
Cause of Trouble
Check Method
Solution
Disconnection or contact
Check for looseness and removal of
●
Correct looseness
failure of signal wire
FC300B board’s connectors CN30,
and/or removal of
between NC unit and AC
CN32.
connectors.
servo drive unit
●
Check looseness and removal of AC
●
Correct wiring as
servo drive unit connectors.
necessary.
●
Perform wiring check according to
Connecting Manual
Failure of PG detector
This type of alarm results when main
Replace FC300B.
circuit connection
power is applied though result of check
Contact your YASKAWA
for above items are normal.
representative.
Motor model parameter
Check if “O” is set to motor model
Set the motor model
setting error.
parameter
to pm1068).
parameter
to
) correctly.
96
Summary of Contents for YASNAC i80
Page 3: ...YASNAC i80 CNC SYSTEM FOR MACHINE TOOLS MAINTENANCE MANUAL v YASUAW14 ...
Page 26: ...1 2 COMPONENTS Cent d 16 14 ACGC Operation Panel Model JZNC IOP1l E u v d 1 2 0 a L ...
Page 30: ... I A om o amvr _ fi___ n ___ __n__n WI c ___________ ...
Page 41: ... Model JANCD FC260 I Ha Approx mass 0 34 kg 1 ...
Page 45: ... rl v JANCD Fc050 1 B r 1 2 q 11 ...
Page 206: ...196 ...