48
Switching LOCAL/REMOTE Mode
The following functions can be selected by switching LOCAL or
REMOTE mode. To select the RUN/STOP command or frequency ref-
erence, change the mode in advance depending on the following appli-
cations.
• LOCAL mode: Enables the Digital Operator for RUN/STOP com-
mands and FWD/REV RUN commands. The fre-
quency reference can be set using the potentiometer
or .
• REMOTE mode: Enables RUN Command Selection (n02). The fre-
quency reference can be set by n03 (frequency ref-
erence selection) setting.
How to Select LOCAL/REMOTE Mode
When LOCAL/REMOTE
switching function is not
set for multi-function
input selection
(When 17 is not set
for any of constants
n36 to n39)
Select Lo for
operator
LO/RE
selection.
Select rE for
operator
LO/RE
selection.
When LOCAL/REMOTE
switching function is set
for multi-function input
selection
(When 17 is set for
any of constants
n36 to n39)
Turn ON multi-
function input
terminal.
Turn OFF multi-
function input
terminal.
REMOTE mode