Table 5.1 User Parameter Settings
Parameter
Description
Default
User Setting
Notes
H4-02
Terminal FM Gain
100.00 %
H4-03
Terminal FM Bias
0.00 %
H4-04
Terminal AM Selection
03h
H4-05
Terminal AM Gain
50.00 %
H4-06
Terminal AM Bias
0.00 %
H4-07
Terminal FM Signal Type
0
H4-08
Terminal AM Signal Type
0
H5-01
Modbus Node Address
1fh
H5-02 Baud
Rate
3
H5-03 Parity
Selection
0
H5-04
Communication Loss Response
3
H5-05
Communication Fault Selection
1
H5-06
Transmit Wait Time
5 ms
H5-07 RTS
Control
Selection
1
H5-10
Unit Selection for Register 0025h
0
H6-01
Terminal RP Selection
0
H6-02
Terminal RP Scaling
1440 Hz
H6-03
Terminal RP Gain
100.00 %
H6-04
Terminal RP Bias
0.00 %
H6-05
Terminal RP Filter Time
0.10 Sec
H6-06 Terminal
MP
Selection
02h
H6-07
Terminal MP Scaling
1440 Hz
L1-01
Motor Overload Fault Selection
1
L1-02
Motor Overload Time Constant
1.0 min
L1-03
Motor OH Alarm Selection
3
L1-04
Motor OH Fault Selection
1
L1-05
Motor Temperature Filter Time
0.20 Sec
L2-01
Power Loss Ride Thru Selection
0
L2-02
Power Loss Ride Thru Time
0.1 Sec
L2-03
Minimum Baseblock Time
0.5 Sec
L2-04
Voltage Recovery Ramp Time
0.3 Sec
L2-05
Undervoltage Detection Level
kVA Dep.
L2-06
KEB Decel Time
0.0 Sec
L2-07
Power Loss Accel Time
0.0 Sec
L2-08
KEB Frequency Gain
100 %
L3-01
Stall Prevention Accel Selection
1
L3-02
Stall Prevention Accel Level
150 %
L3-03
Stall Accel Const HP Level
50 %
L3-04
Stall Prevention Decel Selection
1
L3-05
Stall Prevention Run Selection
1
L3-06
Stall Prevention Run Level
160 %
L3-11
Overvoltage Inhibit Selection
0
L3-12
Overvoltage Inhibit Voltage
Level
kVA Dep.
L4-01
Speed Agree Level
0.0 Hz
L4-02
Speed Agree Width
2.0 Hz
L4-03
Speed Agree Level +/-
0.0 Hz
L4-04
Speed Agree Width +/-
2.0 Hz
L4-05
Frequency Reference Loss Select
0
L4-06
Frequency Reference Loss Gain
80.00 %
L5-01
Number of Auto-Restarts
0
L5-02
Fault Selection During Restart
0
L6-01
Torque Detection 1 Selection
0
L6-02
Torque Detection 1 Level
150 %
L6-03
Torque Detection 1 Time
0.1 Sec
L6-04
Torque Detection 2 Selection
0
L6-05
Torque Detection 2 Level
150 %
L6-06
Torque Detection 2 Time
0.1 Sec
L7-01
Torque Limit Forward Motoring
200 %
Summary of Contents for Varispeed G7
Page 1: ...Modbus Communication Manual G7 Drive Drive Model CIMR G7U Document Number TM G7 11...
Page 2: ...2 Page intentionally blank...
Page 6: ...6 Notes...
Page 10: ...10 G7 Drive Connections Figure 1 2 G7 Drive Connections...
Page 18: ...18 Notes...
Page 32: ...32 Notes...
Page 80: ...80 Notes...
Page 82: ...82 Notes drive drive Name Date...