71
Table 4.12 “N” Parameters
Access Level
Name
Address
Description
Data
Range
Unit
Default
During
Run
V/f
V/f
w/PG
OLV
FV
OLV2
0 Disabled
n1-01 0580h
Hunting Prevention
Selection
1 Enabled
1
1
A A
n1-02
0581h
Hunting Prevention Gain
0.00 ~ 2.50
0.01
1.00
A
A
n1-03
0582h
Hunting Prevention Time
0 ~ 500 ms
1 ms
10 ms
A
A
n2-01 0584h
Speed Feedback Regulator
(AFR) Gain
0.00 ~ 10.00
0.01
1.00
A
n2-02 0585h
Speed Feedback Regulator
(AFR) Filter Time 1
0 ~ 2000 ms
1 ms
50 ms
A
n2-03 0586h
Speed Feedback Regulator
(AFR) Filter Time 2
(Low Speed)
0 ~ 2000 ms
1 ms
750 ms
A
n3-01 0588h
High Slip Braking Decel
Step Width
1 ~ 20 %
1 %
5 %
A
A
n3-02 0589h
High Slip Braking Current
Reference
100 ~ 200 %
1 %
150 %
A
A
n3-03 058Ah
High Slip Braking Dwell
Time at Stop
0.0 ~ 10.0 Sec
0.1 Sec
1.0 Sec
A
A
n3-04 058Bh
High Slip Braking Overload
(OL7) Time
30 ~ 1200 Sec
1 Sec
40 Sec
A
A
n4-07 059Ah
Speed Estimator Integral
Time
0.000 ~ 9.999 ms
0.001 ms
0.03 ms
A
n4-08 059Bh
Speed Estimator
Proportional Gain
0
~
1000
1
15
A
n4-10 059Dh
Observer Proportional Gain
at High Speed (>n4-11)
0.0
~
1000.0
0.1
15
A
n4-11 059Eh
High/Low Speed Observer
Changeover Frequency
40 ~ 70 Hz
1 Hz
70 Hz
A
n4-15 05A2h
Low Speed Regenerative
Coefficient 1
0.0
~
3.0
0.1
0.3 A
n4-17 05A4h
Torque Adjustment Gain at
Low Speed 1
0.0
~
5.0
0.1
1.0 A
n4-18 05A5h
Motor Cable Resistance
Gain
0.90
~
1.30
0.01
1.00 A
n4-28 05AFh
High/Low Speed Observer
Changeover Frequency
During Deceleration
20 ~ 70 Hz
1 Hz
50 Hz
A
n4-29 05B4h
Torque Adjustment Gain at
Low Speed 2
0.00
~
0.40
0.01
0.10 A
n4-30 05B5h
Low Speed Regenerative
Coefficient 2
0.00
~
10.00
0.01
1.00 A
n4-32 05B7h
Speed Estimation Gain
Frequency 1 (Lower Limit
of Low Speed)
0.0 ~ 60.0 Hz
0.1 Hz
5.0 Hz
A
n4-33 05B8h
Speed Estimation Gain
Frequency 2 (Upper Limit
of Low Speed)
0.0 ~ 60.0 Hz
0.1 Hz
20.0 Hz
A
n4-34
05B9h
Speed Estimation Gain Rate
50.0 ~ 100.0 %
0.1 %
100.0 %
A
n4-35
05BAh
U1-48 Reduction Gain
0.50 ~ 1.50
0.01
1.00
A
n4-39 05BEh
Flux Level at Low
Frequency
50 ~ 150 %
1 %
90 %
A
n4-40
05BFh
Current Stabilizing Gain
0.01 ~ 1.00
0.01
kVA Dep.
A
n4-43 05C2h
Speed Estimation
Compensation Gain
0.00
~
2.00
0.01
0.00 A
0 Disabled
n5-01
05B0h
Feed Forward Selection
1 Enabled
1
0
A
A
n5-02 05B1h Motor
Acceleration
Time
0.001 ~ 10.0 Sec
0.001 Sec
kVA Dep.
A
A
n5-03 05B2h
Feed Forward Proportional
Gain
0.00 ~ 100.00
0.01
1.00
A
A
Summary of Contents for Varispeed G7
Page 1: ...Modbus Communication Manual G7 Drive Drive Model CIMR G7U Document Number TM G7 11...
Page 2: ...2 Page intentionally blank...
Page 6: ...6 Notes...
Page 10: ...10 G7 Drive Connections Figure 1 2 G7 Drive Connections...
Page 18: ...18 Notes...
Page 32: ...32 Notes...
Page 80: ...80 Notes...
Page 82: ...82 Notes drive drive Name Date...