6
-128
d5-06
Speed/torque
control
switching timer
Set the delay time from inputting
the multi-function input “speed/
torque control change” (from ON
to OFF or OFF to ON) until the
control is actually changed in ms
units.
This function is enabled when the
multi-function input “speed/
torque control change” is set. In
the speed/torque control switch-
ing timer, the analog inputs hold
the values of when the “speed/
torque control change” changes.
Always be sure to allow time for
this process to finish completely.
0 to
1000
0
No
No
No
No
A
A
29FH
控制切换时间
d5-07
Rotation
direction limit
operation
selection
0: Disabled
1: Enabled
Usually, use a setting of 1
(enabled).
Be sure to enable this setting
when rotating the motor in the
same direction as the speed limit
(winding operation).
0 or 1
1
No
No
No
No
No
A
2A6H
旋转方向限制
动作
H3-04
Signal level
selection (ter-
minal A3)
0: 0 to 10V
1: -10 to 10V
[11-bit + polarity (positive/
negative) input]
0 or 1
0
No
A
A
A
A
A
413H
端子 A3 信号电平
H3-05
Multi-function
analog input
(terminal A3)
function selec-
tion
Select multi-function analog input
function for terminal A3.
0 to 1F
2
No
A
A
A
A
A
414H
端子 A3 设定
H3-06
Gain (terminal
A3)
Sets the input gain (level) when
10 V is input.
Set according to the 100% value
selected from H3-05.
0.0 to
1000.0
100.0
%
Yes
A
A
A
A
A
415H
端子 A3 增益
H3-07
Bias (terminal
A3)
Sets the input gain (level) when
0 V is input.
Set according to the 100% value
selected from H3-05.
-100.0
to
+100.0
0.0%
Yes
A
A
A
A
A
416H
端子 A3 偏置
H3-08
Signal level
selection
(terminal A2)
0: 0 to 10V
1: -10V to 10V
2: 4 to 20 mA (9-bit input).
Switch current and voltage input
using the switch on the control
panel.
0 to 2
2
No
A
A
A
A
A
417H
端子 A2 信号选择
H3-09
Multi-function
analog input
(terminal A2)
function selec-
tion
Select multi-function analog input
function for terminal A2.
0 to 1F
0
No
A
A
A
A
A
418H
端子 A2 设定
H3-10
Gain (terminal
A2)
Sets the input gain (level) when
10 V (20 mA) is input.
Set according to the 100% value
for the function set for H3-09.
0.0 to
1000.0
100.0
%
Yes
A
A
A
A
A
419H
端子 A2 增益
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2