1.3Connection and Wiring
— 1-13 —
Molded-case circuit
breaker (MCCB)
Used to protect
power supply line.
Shuts the circuit
OFF when
overcurrent is
detected.
Noise filter
Used to eliminate external
noise from power supply line.
Power supply:
Single-phase
200 or 100 VAC
Molded-case
circuit breaker
Noise
filter
Magnetic contactor
Turns the Servo
ON or OFF.
Use a surge
suppressor for
the magnetic
contactor.
Model:
HI-Series
Magnetic
contactor
AC/DC power supply
Supplies Servopack
with 24 VDC.
AC/DC
power
supply
Power supply
ground line
Digital Operator
Allows the user to
set parameters or
operation references
and display
operation status or
alarm status.
Personal computers
can also be used.
Personal computer
Connecting cable: JZSP-CFS01 to 03
Encoder cable
Motor cable
JUSP-OP02A-3
Host
Controller
Connect the SGDP SERVOPACK to a
Yaskawa host controller.
MP910, MP920,
MP930, and MP
−
SG1 with a Motion Module
1