YASKAWA
SIEP C730600 0E YAI Modbus TCP/IP Technical Manual
9
Option Contents
Quantity
Z1000, HV600
1
Installation Manual
1
*1
GA500, GA700, and GA800 drives do not use the ground wire.
*2
GA700, GA800, and HV600 drives use two screws only.
*3
LED label has transparent background and white letters. Please make sure that you use the correct label for Z1000 or HV600.
*4
LED labels for Z1000 and HV600 are not packaged with the option if you purchase the option in Japan.
◆
Installation Tools
You can use these tools to install the option to the drive:
•
A Phillips screwdriver or slotted screwdriver (blade depth: 0.4 mm (0.02 in), width: 2.5 mm (0.1 in))
•
A pair of diagonal cutting pliers.
•
A small file or medium-grit sandpaper.
*1
Phillips screw sizes are different for different drive capacities. Prepare different screwdrivers for different
screw sizes.
4
Option Components
◆
Option PCB Components
A - Connector (CN5)
B - Installation hole
C - LED (NS)
D - LED (MS)
E - Ground terminal (FE) and installation hole
F - Port 2 LED (10/100)
G - Option modular connector CN1B (Port 2) (RJ45)
H - DIP switch S1
I - Port 2 LED (LINK/ACT)
J - Port 1 LED (10/100)
K - Option modular connector CN1A (Port 1) (RJ45)
L - Port 1 LED (LINK/ACT)
Figure 4.1 Option PCB Components
*1
Refer to
for more information about the LEDs.
*2
Connect the included ground wire during installation. The ground wire is not necessary for installation on GA700, GA800, and
CR700 drives. For GA500 drives, connect the included ground wire to the separately-sold communication option case (model:
JOHB-GA50).
◆
Communication Connector
The communication modular connector CN1 on the option is a modular dual RJ45 female connector designated
port 1 and port 2. Port 1 and port 2 are the connection points for a customer-supplied male Modbus TCP/IP
network communication cable.