![YASKAWA SGMJV User Manual Download Page 345](http://html1.mh-extra.com/html/yaskawa/sgmjv/sgmjv_user-manual_3746695345.webp)
10 Appendix
10-12
Pn22A
2
Fully-closed Control
Selection Switch
0000 to 1003
−
0000
After restart
Setup
−
Pn230
2
Position Control Expanded
Function Switch
0000 to 0001
–
0000
After reset
Setup
5.8.6
Pn231
4
Backlash Compensation Value
-500000 to
500000
0.1
reference
unit
0
Immediately
Setup
5.8.6
Pn233
2
Backlash Compensation Time
Constant
0 to 65535
0.01 ms
0
Immediately
Setup
Pn281
2
Encoder Output Resolution
1 to 4096
1 edge/
pitch
20
After restart
Setup
8.3.3
Pn304
2
JOG Speed
0 to 10000
1 min
-1
500
Immediately
Setup
6.3
Pn305
2
Soft Start Acceleration Time
0 to 10000
1 ms
0
Immediately
Setup
*1
Pn306
2
Soft Start Deceleration Time
0 to 10000
1 ms
0
Immediately
Setup
∗1.
For details, refer to the
Σ
-V Series/DC Power Input
Σ
-V Series/
Σ
-V Series for Large-Capacity Models User’s Man-
ual MECHATROLINK-II Commands
(Manual No.: SIEP S800000 54).
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Reference
Section
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Speed Feedback Selection at Fully-closed Control
Reference
Section
0
Uses motor encoder speed.
8.3.8
1
Uses external encoder speed.
4th 3rd 2nd 1st
digit digit digit digit
n.
Backlash Compensation Direction
0
Compensates with a reference in the forward direction.
1
Compensates with a reference in the reverse direction.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.