900-200-100 50/57
Parameter
No.
Name
Setting
Range
Units
Factory
Setting
When Enabled
Pc02~Pc0F
Reserved (Do not change.)
* When using SGDV-OSA01A000FT900, Pc0A is displayed on the digital operator. In addition, it is not displayed
on S. However, do not change it regardless of the display conditions.
* Factory setting of reserved parameter is zero.
Pc10
Deceleration Waiting Time A
0 to 10000
10[ms]
0
After resetting
the system
Pc11
Deceleration Monitoring Time A
0 to 10000
10[ms]
500
After resetting
the system
Pc12
Limited Speed A on Waiting for
Deceleration
0 to 10000
Rotational motor: min
-1
Linear motor: mm/s
0
After resetting
the system
Pc13
Limited Distance A
1 to 65535
edge
10
After resetting
the system
Pc14
Limited Constant Speed A
0 to 10000
Rotational motor: min
-1
Linear motor: mm/s
0
After resetting
the system
Pc15~Pc1F
Reserved (Do not change.)
* Factory setting of reserved parameter is zero.
Pc20
Deceleration Waiting Time B
0 to 10000
10[ms]
0
After resetting
the system
Pc21
Deceleration Monitoring Time B
0 to 10000
10[ms]
500
After resetting
the system
Pc22
Limited Speed B on Waiting for
Deceleration
0 to 10000
Rotational motor: min
-1
Linear motor: mm/s
0
After resetting
the system
Pc23
Limited Distance B
1 to 65535
edge
10
After resetting
the system
Pc24
Limited Constant Speed B
0 to 10000
Rotational motor: min
-1
Linear motor: mm/s
0
After resetting
the system
Pc25~Pc4F
Reserved (Do not change.)
* When using SGDV-OSA01A000FT900, Pc25, Pc27 to Pc2F are displayed on the digital operator. In addition,