900-200-100 42/57
9.2.
Monitoring from the Panel Operator and Digital Operator
9.2.1.
Safety I/O Signal Monitor(Un015)
■When using with SGDV-OSA01A
All digits are always shown as being
ON(low level)
(* In this case, monitor is not enabled).
■When using the combination of SGD7S-□□□D□0□ and SGDV-OSA01A000FT900
The safety I/O signal monitor (Un015) is displayed as shown below. The top indicates
OFF (high level)
and the
bottom indicates
ON (low level)
.
Undefined digits (3rd digit to 8th digit) are always shown as being
ON (low level)
.
・SGD7S-□□□D□0□
A condition of SGDV-OSA01A000FT900
A condition of HWBB input signal
to SERVOPACK CN8
Indication of Un015
Safety function A
Safety function B
/HWBB1 input
/HWBB2 input
2nd digit
1st digit
Safety Function is not
active
Safety Function is not
active
ON
ON
ON (low)
ON (low)
ON
OFF
ON (low)
OFF (high)
OFF
ON
OFF (high)
ON (low)
OFF
OFF
OFF (high)
OFF (high)
Safety Function is not
active
Safe (HWBB)
Condition
No effect
No effect
OFF (high)
OFF (high)
Safe (HWBB)
Condition
Safety Function is not
active
No effect
No effect
OFF (high)
OFF (high)
Safety-function-part Alarm
A.EB0, A.EB2, A.EB3, A.EB4, A.EB5, A.EB6
A.EB7, A.EB8, A.EB9, A.EBA
No effect
No effect
OFF (high)
OFF (high)
In this way, when both the Safety function A and B of the Safety Module are not in the Safe(HWBB) state, Un015
shows a input signal condition of the CN8.
When when either the Safety function A or B of the Safety Module are in the Safe(HWBB) state, Un015 shows only
OFF (high level)
regardless of the input signal condition of the CN8
Therefore, when using this monitor, the Safety function of the Safety Module should not be activated.