A-80
[ d ] PARAMETER (parameter)
When RESULT(process result) = 4 (FMT_NG: parameter format error), an error code in the table below is output. Oth-
erwise, the connection number is output.
( 4 ) Connection Number (PARAM02)
Specify the remote source.
When the communication device is Ethernet (218IF or 218IFA), set the connection number.
The following table shows the setting range.
Note: When the communication device is Ethernet (218IF/218IFA), set the connection number in accordance
with the connection number in the 218IF/218IFA Parameter Setting Window for the MPE720 module con-
figuration definition.
Fig. G.10 218IFA Parameter Setting Screen for the MPE720 Module Configuration Definition Window
RESULT (process result)
Code (Hex)
Meaning
When RESULT (process re-
sult) =4
(FMT_NG: parameter format
error)
00
No error
01
Connection number is out of range
02
Time error for monitoring to receive MEMOBUS response
03
Error in setting retransmit count
04
Error in setting cyclic area
05
CPU number error
06
Data address error
07
Data size error
08
Function code error
Others
xx
Connection number
Communication Device
Connection Num-
ber
Remarks
Ethernet (218IF)
1 to 20
Receives from the remote station set for the specified connection number.
Ethernet (218IFA)
1 to 4
Same as above
Summary of Contents for MP2300S
Page 14: ...MEMO...
Page 24: ...MEMO...
Page 114: ...MEMO...
Page 132: ...MEMO...
Page 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program...
Page 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program...
Page 190: ...MEMO...
Page 280: ...MEMO...
Page 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page...
Page 310: ...MEMO...