6.2 Communication with Other MP Series
6.2.3 When MP2300S Acts as Master (I/O message communication function is used)
6-43
6
Ethernet Communications
4.
Create a ladder program with a message receive function (MSG-RCV) in it.
An example of a ladder program for receiving messages in the remote equipment (MP2300) side follows:
Message receive function (MSG-RCV)
Required for receiving messages. Message reception is carried out by inputting and executing this message
receive function in a ladder program.
In addition, in order to support Read and Write by MP2300S, two message receive functions should be provided.
Here, the input item and parameters (Communication buffer channel number and Connection number) of the
message receive function need to accord with the MP2300S side settings.
Note: Similarly, a message receive function with the communication buffer channel number = 6 is required.
Fig. 6.7 MPE720 Module Configuration Definition Window
MSG
RCV
&$
&$
&#
&$
&$
&$
Communication device = Ethernet(218IF)
Protocol type
Circuit number = 1
Communication buffer channel number
Parameter list start address
=DA00000
Execute
Abort
Dev-Typ
Pro-Typ
Cir-No
Ch-No
Param
Busy
Complete
Error
Communication device = 218IF
Circuit number = 1
Summary of Contents for MP2300S
Page 14: ...MEMO...
Page 24: ...MEMO...
Page 114: ...MEMO...
Page 132: ...MEMO...
Page 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program...
Page 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program...
Page 190: ...MEMO...
Page 280: ...MEMO...
Page 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page...
Page 310: ...MEMO...