9-6
155556-1CD
HW0484963
VA1400
9 Maintenance and Inspection
9.2 Notes on Maintenance Procedures
Fig. 9-3: Battery Connection
1. Turn OFF the DX 100 main power supply.
2. Remove the plate fixing screws and the plate on the connector base,
then pull the battery pack out to replace it with the new one.
3. Remove the battery pack from the battery holder.
4. Connect the new battery pack to the unoccupied connector on the
board.
5. Remove the old battery pack from the board.
6. Mount the new battery pack to the holder.
7. Reinstall the plate.
NOTE
Remove the old battery pack after connecting the new one
so that the encoder absolute data does not disappear.
NOTE
Do not allow plate to pinch the cables when reinstalling the
plate.
See replacing step 5.
Connector
See replacing step 4.
New battery pack
Battery pack
before replacement
Circuit Board
(Type: SGDR-EFBA02A)
51 of 85