7.2 Internal User I/O Wiring Harness and Air Line
7-2
173124-1CD
HW1482991
MPL300
II
7.2
Internal User I/O Wiring Harness and Air Line
Internal user I/O wiring harness (0.5 mm
2
x 23 wires), and air lines
(5 lines ) are incorporated in the manipulator for the drive of peripheral
devices mounted on the upper arm as shown in
for Internal User I/O Wiring Harness and Air Line”
The connector pins 1 to 23 are assigned as shown in
. Wiring must be performed by users.
The allowable current for internal user
I/O wiring harness
2.0 A or less for each wire
(The total current value for pins 1 to 23
must be 44 A or less.)
The maximum pressure for the air line 784 kPa (8 kgf/cm
2
) or less
(The air line inside diameter: 7.5 mm)