background image

4  LCD Operator Option Components

14

 

YASKAWA

 TOBP C730600 29C YASKAWA AC Drive-Option LCD Operator Installation Manual

Keys

Refer to 

Figure 2

 and 

Table 6

 for details on key names and functions.

Figure 2

Figure 2  Keys

Table 6  Key Names and Functions

No.

Key

Name

Function

1

Function Key
(F1, F2)

The functions assigned to F1 and F2 vary depending on the menu that is 
currently displayed. The name of each function appears in the lower half 
of the display window. 

For a description of functions assigned to the F1 and F2 keys, 

Refer to 

LCD Display on page 17

.

2

ESC  Key

• Returns to the previous display.
• Moves the cursor one space to the left.
• Pressing and holding this button will return to the Frequency Reference 

display.

3

RESET Key

• Moves the cursor to the right.
• Resets the drive to clear a fault situation.

4

RUN Key

Starts the drive and motor.

LO
RE

F2

F1

ESC

RUN

STOP

ENTER

RESET

ALM

DIGITAL OPERATOR JVOP-180

1

2

3

4

5 6

7

8

9

10

11

F1

F2

R

RU

UN

Summary of Contents for JVOP-180

Page 1: ...180 LCD To properly use the product read this manual thoroughly and retain for easy reference inspection and maintenance Ensure the end user receives this manual Installation Manual LCD Operator YASKA...

Page 2: ...red in a retrieval system or transmitted in any form or by any means mechanical electronic photocopying recording or otherwise without the prior written permission of Yaskawa No patent liability is as...

Page 3: ...ive or sole safety control Without exception all controls should be designed to detect faults dynamically and fail safely under all circumstances All systems or equipment designed to incorporate a pro...

Page 4: ...ese sites Europe http www yaskawa eu com Japan http www e mechatronics com Other areas contact a Yaskawa representative Note Indicates a supplement or precaution that does not cause drive damage 1012...

Page 5: ...afety 6 YASKAWA TOBP C730600 29C YASKAWA AC Drive Option LCD Operator Installation Manual Registered Trademarks Company names and product names listed in this manual are the registered trademarks of t...

Page 6: ...to indicate safety messages in this manual Failure to heed these messages could result in serious or possibly even fatal injury or damage to the products or to related equipment and systems DANGER Ind...

Page 7: ...or the content and presentation of the manual may be changed without notice to improve the product and or the manual When ordering a new copy of the manual due to damage or loss contact your Yaskawa...

Page 8: ...Read and copy drive parameter settings to another Yaskawa drive Operate the drive Monitor drive operation status Note When the LCD Operator Option is installed and connected to the V1000 it will caus...

Page 9: ...h the drive models in Table 2 Table 2 Applicable Drive Models Note Check the LCD operator to make sure it is compatible with the A1000 drive The nameplate on the LCD operator must list software number...

Page 10: ...able 3 Contents of Package Additional Part Required Sold Separately Proper installation of the LCD Operator Option requires a communication cable A communication cable is not provided A connection cab...

Page 11: ...upport Set B 2 Alternate cables customer supplied RJ45 8 pin Straight Connector UTP Cat 5e cable WV001 2 Sold Separately 24 Communication Cable 3 m WV003 2 Sold Separately 24 Installation Support Set...

Page 12: ...tor Option Components LCD Operator Option Figure 1 Figure 1 LCD Operator Option Components A LCD Display D Installation Mounting Holes B ALARM ALM LED E Nameplate C Keys F Communication Cable Connecto...

Page 13: ...y displayed The name of each function appears in the lower half of the display window For a description of functions assigned to the F1 and F2 keys Refer to LCD Display on page 17 2 ESC Key Returns to...

Page 14: ...2 8 ENTER Key Enters parameter values and settings Selects a menu item to move between displays 9 LO RE Selection Key Switches the drive between operator LOCAL control and control circuit terminals RE...

Page 15: ...re 3 RUN LED Status Flashing Quickly 1 Off LO RE LED When the run command is selected from the LCD operator LOCAL Run command is selected from a device other than the LCD operator REMOTE RUN LED Durin...

Page 16: ...when in Monitor Mode VERIFY Indicates the Verify Menu PRMSET Displayed when in Parameter Setting Mode A TUNE Displayed during Auto Tuning SETUP Displayed when in Setup Mode 2 DriveWorksEZ Function Sel...

Page 17: ...command is supplied from the operator keypad RREF Displayed when the frequency reference is supplied from a remote source LREF Displayed when the frequency reference is supplied from the operator keyp...

Page 18: ...tallation Manual 19 ALARM ALM LED Displays Table 9 ALARM ALM LED Status and Contents State Content Display Illuminated When the drive detects an alarm or error Flashing When an alarm occurs When oPE i...

Page 19: ...Use only Yaskawa connection cables or recommended cables Failure to comply may cause the drive or LCD Operator Option to function incorrectly Properly connect the connectors Failure to comply may prev...

Page 20: ...ed inside a panel Table 10 LCD Operator Option Installation Methods Installation Method Description Notes External Face mount Simplified installation with the LCD Operator is mounted on the outside of...

Page 21: ...gure 8 2 Position the LCD Operator Option so the LCD display faces outwards and mount it to the enclosure panel as shown in Figure 7 Figure 7 Figure 7 External Face mount Installation Figure 8 Figure...

Page 22: ...g to Figure 10 2 Mount the LCD Operator Option to the installation support sold separately 3 Mount the installation support and LCD Operator Option to the enclosure panel Figure 9 Figure 9 Internal Fl...

Page 23: ...nected LCD Operator Option Note Use only Yaskawa recommended cables Using a cable not specified may cause the LCD Operator or drive to malfunction Note The STOP key on the drives built in LED operator...

Page 24: ...OPR Rdy MONITR FREF d1 01 U1 01 000 00Hz 3 4 0 00 60 00 0 00Hz DRV FWD Rdy MODE U1 01 0 00Hz U1 02 0 00Hz U1 03 0 00A DRV Monitor Menu Rdy MODE PRG Modified Consts HELP HELP DATA MODE PRG Quick Setti...

Page 25: ...edure LCD Display 1 Apply main power to the drive The Frequency Reference appears after the initial display on the LCD Operator Option 2 Press to show the Frequency Reference display If b1 01 is not s...

Page 26: ...eference display 2 Press until the Monitor Menu display appears 3 Press to show the Monitor display 4 Press to view the drive monitors RUN MONITR FREF d1 01 U1 01 006 00Hz 0 00 60 00 0 00Hz DRV FWD Rd...

Page 27: ...1 Frequency Reference 2 Press to select the Programming Mode 3 Press to show the Initialization display 4 Press to select A1 00 and press 5 Press to enter setting 1 MODE U1 01 0 00Hz U1 02 0 00Hz U1 0...

Page 28: ...and the LCD Operator Option will display Japanese Procedure LCD Screen 1 Frequency Reference diplay 2 Press to select the Programming Mode 3 Press to show the Initialization display 4 Press to select...

Page 29: ...tor Option can perform the Read function an estimated 100 000 times Copy Copies the parameter settings from the LCD Operator Option to another Yaskawa drive Verify Verifies that parameter settings in...

Page 30: ...settings in the LCD Operator Option Procedure LCD Screen 1 Frequency Reference display 2 Press to select the Programming Mode 3 Press to show the Initialization display 4 Press to select o3 01 and pre...

Page 31: ...9C YASKAWA AC Drive Option LCD Operator Installation Manual 6 Press and the LCD Operator Option will read the parameter settings from the drive 7 Automatically return to the Copy Function Selection di...

Page 32: ...input terminal A1 or A2 2 MEMOBUS Modbus serial communications 3 Option PCB 4 Pulse Input Terminal RP 1 b1 02 Run Command Selection 1 Selects the run command input source 0 Operator RUN and STOP keys...

Page 33: ...s drive action when the LCD Operator Option is removed in LOCAL mode or with b1 02 0 0 The drive will continue operation 1 The drive will trigger a fault oPr and the motor will coast to stop 0 o3 01 C...

Page 34: ...es department if the cable appears to be connect properly but still no message appears to indicate the error Table 12 Fault Error Code Displays LCD Operator LED Operator Description 1 LCD Operator Opt...

Page 35: ...Disconnect LCD Operator Option Connection Fault oPr Data should appear on the LED operator By reconnecting the LCD operator to the drive data should also appear on the LCD Operator display An oPr faul...

Page 36: ...C 1 1 The LCD display may respond more slowly if the ambient temperature falls below freezing Higher temperatures can also shorten the performance life of the LCD display Humidity up to 95 RH no conde...

Page 37: ...Date of Published Rev No Section Revised Content November 2007 First edition June 2008 Back cover Revision Address August 2008 All Chapters Revision The title of the manual Revision Application to the...

Page 38: ...085 U S A Phone 1 847 887 7000 Fax 1 847 887 7370 YASKAWA ELETRICO DO BRASIL LTDA Avenida Fagundes Filho 620 Sao Paulo SP CEP 04304 000 Brazil Phone 55 11 3585 1100 Fax 55 11 5581 8795 YASKAWA ELECTRI...

Reviews: