3 Utility Function Mode
3.2.15 Write Prohibited Setting (Fn010)
3-38
(2) Operating Procedure
Follow the steps to set enable or disable writing.
Note: To make the setting available, change the setting to P.0000 as shown in step 3.
Step
Display after Operation
Keys
Operation
1
Press the
Key to view the main
menu for the utility function mode.
Use the
or
Key to move
through the list and select Fn010.
2
Press the
Key. The display
changes to the Fn010 execution dis-
play.
3
Press the
or
Key to
select one of the following settings.
P.0000: Write permitted [Factory set-
ting]
P.0001: Write prohibited
4
Press the
Key. The setting value
is written into the SERVOPACK, and
the status display changes as follows:
“DONE” to “BB.”
Note: Saved settings will be enabled
after the SERVOPACK is
restarted.
5
Turn OFF the power and then turn it ON again to validate the new setting.
B B
−
F U N C T I O N
−
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 0
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 1
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 1