Parameter/Monitor Modes
2.1 Parameter Mode
2-3
∗
When the setting is modified, the parameters whose modified setting is validated only after
setting validation, the warning A.941 “Change of Parameters Requires the Setting Valida-
tion” is displayed. Turn the power OFF then ON to clear the warning and validate the new
setting.
4
Press the
Key to move the cur-
sor to the setting side (to the position of
the first digit of Pn000.0).
5
Press the
Key once to set “1”
for the first digit of Pn.000.0.
6
Press the
Key.
The new setting of Pn000 is written to
the SERVOPACK. The cursor moves to
the parameter number side and the
warning A.941 is displayed.
7
To enable the change in the setting, turn the power OFF and ON again.*