32
Cables / Peripheral Devices
Cables / Peripheral Devices
Model
Manufacturer
Contact
JUSP-RG08D
Resistance
Allowable
regenerative energy
Regenerative
operating voltage
Regenerative
processing current
Error detection
Alarm output
50
Ω
12W
380 Vdc
8 Adc
Disconnection of regenerative resistance,
failure of regenerative transistor, or overvoltage
NC contact (Opens if a protective function is used.)
Contact specifications: 250 VAC, 1.5A (inductive load)
Approx. mass : 1.0kg
6
25
50
160
15
130
15
6
5
25
149
130
(15.5)
Nameplate
6-dia. hole
M4 screw for ground terminal
(Y4)
(Y5)
YASKAWA
C1
C2
+(Y3)
-
AL-0V
AL-RE
RE-ON
POWER
REGENERATIVE UNIT
JUSP-RG08D
Regenerative Unit
Dimensions
Internal Connection Diagram
4.2 dia.
±
0.5
Case
Connection
cables
11
±
1
28.5
±
1.0
28
±
1
200
+30 -0
5.5
±
1.0
4.5
±
0.5
41
±
1
1 2
1
2
Model
Manufacturer
Contact
Okaya Electric
Industries Co., Ltd.
OKAYA HONG KONG
TRADING LIMITED
Single-phase
250 VAC
Specifications
R
C
M-601BQZ-4
Surge Protector (For lightning surge protection)
M4 screw for external terminal
Specifications
Specifications
Dimensions
Units: mm
Dimensions
Units: mm
Yaskawa Electric
Corporation
YASKAWA
ELECTRIC
(SHANGHAI)
CO.,LTD.