3.2 Function Modules
USB Memory
3-86
4.
Set the INIT pin on the mode switch 1 on the CPU Unit according to the register type to load.
5.
Turn ON the power supply to the CPU Unit.
The batch load operation starts.
The progress of processing will be shown on the display during the batch load operation as follows:
6.
Turn OFF the power supply to the CPU Unit.
7.
Remove the USB memory device from the USB connector on the CPU Unit.
8.
Turn OFF the LOAD pin on the mode switch 1 on the CPU Unit.
9.
Turn ON the power supply to the CPU Unit.
Batch Saving to USB Memory
1.
Turn ON the power supply to the CPU Unit.
2.
Make sure the security password has not been set for the CPU Unit.
Otherwise, any attempts to perform a batch save will fail. Refer to the following manual for details on the
security password.
MP2000/MP3000 Series Machine Controller System Setup Manual
(Manual No.: SIEP C880725 00)
3.
Insert the USB memory device that contains the application data to save into the USB connector
on the CPU Unit.
Registers to
Load
INIT Switch Setting
OFF
ON
M registers
Transferred.
Not transferred.
G registers
Not transferred regardless of DIP switch setting.
S registers
I registers
O registers
C registers
Always transferred regardless of DIP switch setting.
# registers
D registers
If the load operation fails, an error code will be displayed on the display on the CPU Unit.
Refer to the following manual to troubleshoot the problem, then perform the batch load again.
MP3000 Series MP3200 Troubleshooting Manual
(Manual No.: SIEP C880725 01)
When a save operation is performed to the USB memory device, any data that is stored on the USB
memory device will be overwritten.
Information
Note